MEC&F Expert Engineers : 11/02/14

Sunday, November 2, 2014

SUBROGATION OF FIRE LOSSES

SUBROGATION OF FIRE LOSSES





Most common Construction Defect Repair issues we have Investigated regarding Fires

Pyrolysis: The Result of Improper Fireplace Installation or Lack of Maintenance

When combustible objects are placed too close to a heat source at temperatures of 212°F or more for a long period of time, a chemical breakdown or decomposition called pyrolysis can occur.  Pyrolysis is a major cause of fires throughout North America.  Every year many tragedies and fires are caused by pyrolysis and yet most people don’t know what it is or the importance of preventing it.  Understanding the potential presence of the threat is where prevention of this little-known danger begins.

Materials break down chemically as they dry out due to exposure to extreme heat.  Essentially the ignition temperature of the material is lowered so that they ignite much more easily than it was possible before.  Severely pyrolyzed wood can ignite at only 212 degrees F, while it would normally have a catch-fire temperature of about 500 degrees F, before it had any exposure to intense heat.  Eventually the pyrolyzed wood will ignite, and a direct flame is not required for the fire to start.  All that is required for pyrolysis to occur is heat and oxygen.

METROPOLITAN’s fire investigators say that of all the solid fuel-related fires they have investigated are caused by pyrolysis over 86% of the time.  About 10% of the fires they have investigated were caused by improper installation or failure of the seals, connectors, appliance, piping, valves, or chimney.  Another 4% of the fires have been caused by careless use or improper maintenance of heating systems.



What Causes Pyrolysis?
Pyrolysis is practically an inevitable event when fireplaces, fireplace inserts, solid-fuel stoves and furnaces are installed improperly or the system is not maintained to prevent the escape of hot gases into the combustible components.  The tragedies resulting from pyrolysis are completely preventable.  All that needs to be done is to ensure that the amount of space between a wood-burning stove, stovepipe, and other heating appliances is at least the minimum recommended by the manufacturer.  

 It is also very common to see fires caused by pyrolysis in the latter years of a fireplace, when the system has deteriorated with time, allowing gases to escape through small gaps in the liner, failing mortar joints, etc.  The numerous freeze-thaw cycles that all chimneys in the north America have been subjected to, will eventually cause the chimney structure to fail, and the liner to be cracked.  A cracked liner puts the home at risk for a dangerous housed fire due to the effects of the pyrolysis.  It may not happen in one year or ten years – but eventually the wood will be catching fire from the escaping gases through the small cracks in the liner or other places of the fireplace.

It is common for unprotected furnishings, walls, and other combustible structural components to be placed too closely to heat sources.  Because everything seems fine for months or even years, homeowners fail to realize that the process of pyrolysis is occurring and could unexpectedly result in a fire at any time.

Pyrolysis is also caused by a damaged chimney liner. Even the smallest amount of deterioration in the chimney liner or the deterioration of seals and joints or the lack of sealants can cause nearby combustibles to catch fire from the escaping gases.

Insufficient Clearances between Fireplaces and Combustible Materials.
Insufficient clearances between fireplaces and combustible materials can be a serious construction defect.  The construction, placement, chosen material, and other aspects of fireplaces have to adhere to certain regulations and building codes.  These regulations and building codes are in place to look out for the safety of the inhabitants of a building. They can be strict but they do serve a public purpose. Not being compliant with these restrictions can result in a hazardous situation. Insufficient clearances between fireplaces and combustible materials are fire hazards.
Clearances to combustibles is something they didn’t worry about in the old days. It is quite common to see wood beams or 2x4s right against the masonry of a chimney.  When there are fires in old homes, it’s also common to find that some of this wood ignited. Oddly enough, the process of pyrolization takes place over many, many years. The unscientific definition of that is that the ignition temperature of wood gets lower over time. In other words, it takes less heat to catch it on fire 50 or 100 years later than when it was new.



Use of Non-Approved Decorative Chimney Terminations.
Use of non-approved decorative chimney terminations is a common problem that many homeowners may have, unbeknownst to them. A construction defect like this may only become evident to a homeowner when there are some obvious issues, such as excessive smoke collection or when products of combustion are venting into the dwelling. If you are having issues with the functioning of your fireplace and chimney you may need to verify that use of non-approved decorative chimney terminations is not the issue.

Non-manufacturer approved accessories installed into fireplace.
Due to the strict requirements and testing process, all manufacturers require that only manufacturer approved parts be used in conjunction with their fireplaces. By using aftermarket glass doors, refractories and other fireplace components that aren’t approved by the original manufacturer, there is a risk of voiding the UL listing and the warranty, creating a liability issue for the person or person(s) providing the services or even for the homeowner.

The chimney structure or flue or connections to the fireplace have become settle, separated or disconnected
Based on our forensic investigations, we see that gaps have been created around the chimney structure or around the liner or the firebox.  This resulted in hot gases escaping the fireplace and drying out the wood around it.  As we stated earlier, the process of pyrolization takes place over many, many years.  And one fatal year, the wood finally burns and causes extensive damage and loss of life.

There are many reasons this shifting or disconnection can happen.  At times, it could be a construction defect, or installer error.  Many times we observe inadequate mortar or missing mortar due to lack of maintenance or installation of incorrect type of mortar.  It is not uncommon to observe lack of seal between the firebox and the lintel at the top of the firebox – this is a common construction defect leading to fires as the escaping gases will slowly pyrolize the wood framing.

Other times, the flue may have shifted in an earthquake, or a metal strap supporting a bend in the system could have failed.  At other times, the chimney moves due to severe weather (excessive freeze-thaw cycles, heavy winds, erosion, flooding, and so on).  There are also instances where a chimney sweep unfamiliar with prefabricated metal fireplace systems may have disconnected the flue in the process of cleaning the flue, or removing the cap.

Leaking Gas Connections had led to Fires
After gas line is connected, it is a code requirement  that each appliance connection, valve, valve train, shall be checked while under normal operating pressure with either a liquid solution, or leak detection device, to locate any source of leak.  Tighten any areas where bubbling appears or leak is detected until bubbling stops completely.  DO NOT use a flame of any kind to test for leaks.

Leak test with a soap solution after installing or servicing with main burner on.  Coat pipe and tubing joints, gasket etc. with soap solution. Bubbles indicate leaks.  Tighten any areas where the bubbles appear until the bubbling stops completely.

Before performing any service on the appliance, ensure the gas has been completely shut off, the unit cooled, and the electricity shut off to the appliance.  The burner and valve control compartments must be cleaned annually.  A vacuum with a brush attachment works well. The logs should be cleaned gently with a soft bristle brush. The logs are fragile and are easily damaged.

Miscellaneous Fireplace Construction Defects
Several times we have observed missing or blocked out cleanout pits.  Oftentimes during renovation of old homes, we see that the fireplace ash pits are covered to create a finished room.  This has created fire hazards as the ash inside the pit will ignite when enough of it accumulates inside the ash pit.
At other times, the valves inside the fireplace will get clogged with debris (pet hair, ash, dust, etc.).  Sometimes these valves are improperly installed and they leak, creating fire hazards.

Finally, we often see that manufacturer’s instructions are not followed during fireplace installation.  The key point to make here is that all equipment and appliances and instruments have a certain operating range that if exceeded due to improper construction or installation or maintenance, these components will fail causing property damage and loss of life.

As we noted earlier, if subrogation is contemplated, it is important to notify potential responsible parties to inspect the scene, prior to evidence removal and storage, in order to avoid spoliation claims.




SUBROGATION ASSOCIATED WITH LOSSES CAUSED BY VENTLESS FIREPLACES


Ventless fireplaces have resulted in a number of losses caused by design failures, as well as failures caused by lack of regular maintenance or abuse.  These fireplaces can be inspected for the following defects or hazardous conditions:

       A gas leak. During production, installation or servicing, a leak can be created;
       plugged burner ports. The contractor may accidentally plug the burner ports while spreading ceramic tile over the burners, or they may be painted over at the factory. The resulting unbalanced burn will create excessive carbon monoxide;
       a clogged burner. Dust, carpet lint and pet hair can gradually choke off the fireplace’s air supply, leading to incomplete combustion and high amounts of carbon monoxide that are vented into the living space;
       high gas-input rate. Excessive carbon monoxide ventilation or overheating of the unit will result from firing the gas higher than the input rate set by the manufacturer’s specifications. This can be caused by high gas-supply pressure, an incorrect orifice drill size done at the factory, or if the installer gives the customer's unit a larger flame for aesthetic reasons;
       the fireplace is oversized for the square footage of the area to be heated.
       a cracked burner. The gas burner may develop a crack over time and function erratically, producing high levels of carbon monoxide;
       the fireplace contains items other than the artificial logs designed for the unit. Problems caused by the incineration of firewood or other flammable items will be immediate and extreme. A more likely and less obvious hazard is created by adding pebbles, lava rocks, and other non-combustible aesthetic touches to the fireplace, as their exposure to flames will cause an unsafe rise in levels of carbon monoxide; and  
       a missing or defective oxygen detection sensor.  As these components may fail, it is advisable to install a carbon monoxide detector near a ventless fireplace and, ideally, in other rooms, as well.


In summary, ventless fireplaces, while attractive and portable, suffer from a design flaw that may allow dangerous gases to enter the living space.

As we noted earlier, if subrogation is contemplated, it is important to notify potential responsible parties to inspect the scene, prior to evidence removal and storage, in order to avoid spoliation claims.





SUBROGATION SERVICES AT METROPOLITAN
METROPOLITAN has broad experience handling subrogation claims arising from water, fires, explosions, construction defects, product failures, energy and oil release claims, and boiler and machinery failures.  Our cases range from highly complex commercial losses to smaller scale business and personal lines claims.  Claims we handle include:




  • alarm/security
  • boiler
  • building, roof, crane collapses
  • building system failures
  • chemical explosions
  • construction defects
  • earth movement
  • electrical failures
  • employee dishonesty
  • environmental
  • explosions
  • fires
  • floods
  • geotechnical failures
  • grill malfunctions
  • industrial accidents
  • industrial equipment failures
  • machinery and equipment failures
  • mechanical failures
  • mold
  • natural gas explosions
  • product liability
  • sewer back-up
  • steam line failures
  • spontaneous-combustion fires
  • spread fires

We routinely involve our teams of origin and cause investigators; civil, structural, geotechnical, electrical, mechanical, metallurgical, materials, and automotive engineers; combustion scientists; fire protection specialists; certified fraud examiners; accountants; law enforcement; and coverage counsel in the underlying claim to analyze and determine the causes of losses and accidents.  We work with outside or insurer counsel to ensure thorough analysis, proper evaluation of losses, and to exhaust and/or eliminate alternative theories.  We, along with the team of lawyers, develop non-destructive and destructive testing protocols, coordinate transfer of evidence and preservation of evidence.

Metropolitan Engineering, Consulting & Forensics (MECF)

Providing Competent, Expert and Objective Investigative Engineering and Consulting Services
P.O. Box 520
Tenafly, NJ 07670-0520
Tel.: (973) 897-8162
Fax: (973) 810-0440
E-mail: metroforensics@gmail.com
Web pages: https://sites.google.com/site/metropolitanforensics/
https://sites.google.com/site/metropolitanenvironmental/
We are happy to announce the launch of our twitter account. Please make sure to follow us at @MetropForensics or @metroforensics1
Metropolitan appreciates your business.
Feel free to recommend our services to your friends and colleagues.
 



SUBROGATION OF CLAIMS ARISING FROM BOILER, INDUSTRIAL MACHINERY & EQUIPMENT FAILURES




SUBROGATION OF CLAIMS ARISING FROM BOILER, INDUSTRIAL MACHINERY & EQUIPMENT FAILURES


This blog is intended to assist the claims professional in protecting the insurer’s subrogation interests in losses arising from BOILER, INDUSTRIAL MACHINERY & EQUIPMENT FAILURES, including losses caused both by electrical and mechanical anomalies and malfunctions.  These frequently complex claims present unique recovery challenges.  The machinery or equipment that failed may be old and original purchase records as well as complete repair and maintenance records may be unavailable.  Insureds may begin repairs and reconstruction of the equipment before or shortly after notifying the carrier.  In such situations, a proper investigation into the cause of the failure may not be possible and evidence crucial to a subrogation claim may be lost or destroyed.
This blog will provide an overview of the subrogation specific issues that often arise with these types of claims. It should serve as a guide to the property and subrogation professional to insure that the evidence necessary for pursuing claims against responsible third parties is gathered and preserved from the onset of the investigation. As with any substantial loss, the adjuster is advised to retain counsel in a timely manner to oversee the investigation of the loss and fully explore subrogation potential.
A. COMMON TYPES OF LOSSES
There are a variety of claim scenarios that an adjuster may encounter in handling equipment and machinery losses, including:
(1) failure of industrial machinery or equipment which may halt production in a plant and/or damage other property;
(2) failure of a turbine generator, with resulting interruption of power;
(3) failure of an electrical transformer with a resulting power outage or electrically induced fire;
(4) an electrical anomaly or power surge which impacts the insured’s electrical system and electric or electrical equipment, damages other equipment, leads to a loss of power and/or starts a fire;
(5) failure of a refrigeration or HVAC system which causes death of livestock or spoilage of goods due to loss of ventilation or temperature changes;
(6) failure of a compressor or pump in a hydraulic system leading to a rupture or release of fluids with explosive force;
(7) failure of a boiler with catastrophic consequences, including explosive damage and ensuing fires.
B. INVESTIGATION
The adjuster should instruct the insured not to begin repairs until the condition of the machinery or equipment can be examined and documented, and where practicable, the appropriate parties placed on notice of the loss and given the opportunity to examine the damaged items. Generally, an expert, such as a mechanical or electrical engineer, will need to inspect the damaged equipment to determine the precise mode of failure and cause of the loss.
Regardless of the specific type of loss at issue, the claims handler needs to act promptly to insure that a proper investigation into the cause of the loss is conducted and to make certain that all relevant evidence and information is identified and collected. Any component parts that are replaced need to be preserved.
1. MACHINERY AND EQUIPMENT LOSSES
To assist any retained experts with their investigation and to enable counsel to evaluate a machinery or equipment loss for subrogation potential, the adjuster should ask the following questions and try to gather the following documents and information from the insured:
(a) INSTALLATION
·         How old is the machinery or equipment that failed?
·         Who installed the machine?
·         Is there a written warranty from the manufacturer/installer?
·         Was there a written contract with the seller/installer?
·         Were written or oral start-up instructions provided?
(b) OPERATION
·         What is the purpose of the machine and how was it being used at the time of failure?
·         Who was operating the machine at the time of failure?
·         Where specifically was the operator at the time of failure?
·         What happened? What was seen, heard, smelled?
·         Did the manufacturer/seller/installer provide written or oral operating instructions?
·         Were any written or oral warnings provided prior to the loss?
(c) MAINTENANCE/REPAIR HISTORY
·         Is there a service/maintenance contract or agreement with an outside contractor for the machine?
·         Is there a preventative maintenance program for the machine?
·         Was any preventative maintenance recommended by the seller, manufacturer or installer?
·         Are there maintenance records and invoices?
·         What was the planned or implemented maintenance schedule for the machine?
·         Was the machine modified by anyone prior to the loss?
·         Have any parts of the machine been replaced in the past?
·         Were there any recent problems with the machine or have repairs been performed?
2. ELECTRICAL EVENTS
When a loss appears to have been caused by an electrical anomaly or malfunction, the adjuster should ascertain the name of the electric utility providing service to the insured, inquire into past problems or unusual occurrences, and gather specific information about any abnormal electrical events immediately preceding the loss.  The adjuster also should note the location of any outside meters, power lines and transformers and these items should be inspected for evidence of a failure. In most instances, an electrical expert will be needed to investigate the specifics of the loss and to gather particular information about the utility’s electrical distribution system and protective devices.
C. THEORIES OF RECOVERY
1. MACHINERY AND EQUIPMENT LOSSES
In losses involving industrial equipment and machinery, subrogation may be pursued against the manufacturer, seller and/or installer of the equipment as well as any service or maintenance companies who worked on the equipment.  Parties may be held responsible under products liability case law or statutes, consumer protection statutes, common law negligence principles, the Uniform Commercial Code or the terms and conditions of any contract with the insured. Subrogation may be pursued for:
 (a) Manufacturing defects. The manufacturer or seller may be liable for supplying a machine with faulty components or for assembling the machine improperly.
(b) Defective design. The manufacturer or seller may be liable for failing to design the machine with appropriate safety features, such as high temperature or low fluid shut-offs.
(c) Improper installation. The manufacturer may be liable for failing to provide appropriate installation instructions for the machinery or the installer may be liable for failing to follow the manufacturer’s instructions and/or failing to comply with any applicable standards and codes, such as by placing the machinery too close to combustibles or using undersized electrical wiring.
(d) Improper repairs or maintenance. An outside service company may be liable for failing to inspect, test and repair the machinery in accordance with the manufacturer’s specifications and good industry practices.
(e) Improper or inadequate operating instructions or warnings. The manufacturer, seller or installer may be liable for failing to provide adequate warnings regarding the operation of the machinery and any dangers inherent in its use.
(f) Breach of contract. The manufacturer, seller, installer and any repair or maintenance company may be liable for the failure of the machinery to operate and perform as promised, pursuant to a written or oral contract.
(g) Breach of warranty. The manufacturer, seller, installer and any repair or maintenance company may be liable for breach of any oral or written warranties, including a warranty that the machinery was safe and suitable for a particular purpose.
2. ELECTRICAL EVENTS
Equipment and machinery may be damaged by electrical malfunctions such as a voltage surge or “out of phase” power. Goods or livestock also may be adversely affected by a loss of power and/or damage to an HVAC system or from the failure of related equipment. Subrogation should be evaluated against an electric utility or electrical/mechanical contractor for the following:
(a) Improper placement of a transformer. It is well-recognized that there is a danger of fire when a transformer fails due to the flammable insulating fluids (mineral oil) inside the transformer. Accordingly, the National Electric Code requires an installer to consider this risk of fire and to take appropriate safeguards when installing a transformer near a building, such as installing the transformer in a fireproof enclosure, providing a fire-resistant barrier, automatic extinguishing system and/or maintaining a safe distance between the transformer and any adjacent structures. A utility or independent contractor may be liable for failing to provide such safeguards when a transformer fails catastrophically and ignites an adjacent building.
(b) Uncoordinated electrical overcurrent protection in an electrical distribution system.
Electrical failures should be expected by utilities.  Occurrences such as power lines being damaged during storms are not uncommon. Utilities must provide appropriate protection in the form of fuses and circuit breakers. Fuses and circuits do not prevent electrical failures, instead, they mitigate the damage that can be caused by a failure.
Utilities must select and install properly sized fuses in their electrical distribution systems to protect transformers and other equipment from overcurrents or out of phase power, which can cause electrical equipment to overheat and fail, sometimes catastrophically.
(c) Improper maintenance. Utilities may be liable for failing to maintain their electrical distribution systems, including the failure to trim tree branches where they may interfere with power lines.  Utilities also may be liable for reconnecting power to damaged circuits without confirming that the circuits and attendant electrical equipment are undamaged and functioning properly.
 (d) Improper response to requests for troubleshooting.
Utilities may be liable in certain situations for failing to respond appropriately to a customer’s requests for service or repairs.
D. SIGNIFICANT ISSUES AFFECTING RECOVERY
1. ECONOMIC LOSS DOCTRINE
A majority of states have adopted the economic loss doctrine, which precludes a party from bringing a tort action, such as a negligence or products liability claim, to recover strictly economic damages resulting from the failure of a defective product.  Economic damages include the cost to repair or replace a defective piece of equipment or machinery and any business interruption loss or extra expenses that result from the failure of the equipment or machinery.  In such situations, where a party’s damages are solely economic, the party’s remedies against a seller are limited to those which were provided in the contract of sale or which exist under the Uniform Commercial Code (“UCC”).
The UCC is a national sales code which governs the sale of commercial goods. The UCC may permit recovery for breach of the implied warranty of merchantability or fitness for a particular purpose, or for breach of express warranties. Unfortunately, UCC claims typically must be brought within four years of tender of delivery (i.e., purchase), which precludes claims for products older than four years. Further, the UCC permits sellers to disclaim warranties and strictly limit a party’s remedies, which sellers often do in their sales contracts.  This may leave a buyer without recourse.
Further, the economic loss doctrine may prohibit a negligence claim against a service provider unless the offending party breached a duty of care which exists independent of the contract. Thus, a party which negligently services or maintains a machine and causes damage to the machine or otherwise causes the insured to suffer economic losses may be immune from a negligence suit. In such cases, the insured would be limited to whatever remedies were provided under the service contract.  However, service providers often exclude any implied warranties under their contracts, disavow any liability for consequential damages and limit the applicable period for any warranties.
The harshness of the economic loss doctrine varies state by state. Some jurisdictions allow an injured party to recover for damages to a product itself, while others allow a negligence claim when a product fails suddenly or catastrophically, as opposed to wearing out over time. Nevertheless, even in the more restrictive states, recovery is often permitted for damages to property other than the product itself.  Thus, when a machine or equipment causes a fire, generates smoke, or releases fluids, recovery for the damages to the other property in the premises generally is allowed.
The economic loss doctrine is subject to varied interpretations by courts even within the same jurisdiction. The complexity of this doctrine, and its potential ability to bar or limit even the most meritorious of subrogation claims, demands the early retention of specialized recovery counsel to make sure time restrictions are recognized and recovery opportunities are effectively pursued.
2. SPOLIATION OF EVIDENCE
In recent years, spoliation of evidence has been the subject of increased focus by the courts.  Spoliation includes the failure to retain material evidence, alteration of evidence and/or the loss or destruction of evidence. Litigants increasingly are arguing that physical artifacts from a loss site must be preserved and that the unavailabilty of evidence irreparably prejudices their case.  Courts have shown an increased willingness to impose sanctions against offending parties. Such sanctions may include an adverse inference instruction to a jury, the exclusion of certain evidence from trial, and even, in certain circumstances, preclusion of expert testimony, or the outright dismissal of a claim.
To avoid spoliation concerns, it often is advisable to identify potential defendants, place them on notice of a loss and provide them with an opportunity to inspect a loss site or piece of machinery prior to any repairs being conducted. In situations where this is not feasible, due either to severe time constraints or the inability to immediately identify potentially responsible third parties, the claims handler should be certain to photograph and document the loss site thoroughly. This includes recording of fluid levels in a machine, documenting control settings, noting environmental conditions and interviewing operators and maintenance personnel.  Further, all components of a machine or equipment that are replaced must be preserved.
3. STATUTES OF REPOSE
Many states limit the period of time for which a seller or manufacturer can be held liable for supplying a defective product.  For example, in some states, an aggrieved party cannot bring an action against a manufacturer for supplying a defective product if the product is more than ten years old.  The stated policy of these statutes is to prevent a manufacturer or seller from being responsible indefinitely for defects in all of the products that they have made or sold.
A statute of repose is different from a statute of limitation.  A statute of limitation typically begins running on the date when the cause of action accrues and sets the period of time within which a lawsuit must be filed. For example, in states with a two year statute for negligence, an action must be must be commenced within two years from the date of loss.  A statute of repose, however, sets a time limit from the date of sale of a product for how long the manufacturer or seller can potentially be held liable for a defect in the product. A statute of repose may extinguish a potential cause of action before the loss even occurs.  Thus, if an insured purchases a piece of equipment which fails and causes a fire in the eleventh year of operation, there may be no recovery from the manufacturer or seller if there is a ten year statute of repose.
Some jurisdictions also have statutes of repose for the construction of improvements to real property.  These statutes may bar a claim against a contractor, architect or engineer for deficient construction of the building, as well as for improper installation of building fixtures. The issue is whether the improvement or fixture will “run” with the property.  Factors relevant to this analysis may include the nature of the equipment, its purpose and use, and whether it was purchased separately from the building.
4. OPERATOR ERROR
The adjuster should ascertain the names of all employees operating or observing a machine at the time of failure. These employees need to be questioned about their training and experience and the circumstances surrounding the operation of the machine immediately before the loss. Often, a loss is caused by the operator’s failure to follow prescribed procedures, such as maintaining proper fluid levels. Nevertheless, a seller or manufacturer may be liable for failing to provide adequate instructions or warnings to the user or for failing to incorporate appropriate safety mechanisms into the machine.
5. UTILITY TARIFFS
When a loss is caused by a malfunction in equipment owned by an electric utility, such as a transformer or power distribution lines, or by negligent maintenance procedures by the utility, it is necessary to evaluate tariffs that may protect the utility. Tariffs have the force of law. In some jurisdictions, an electric utility is shielded from liability unless the utility was grossly negligent. Some jurisdictions also limit recovery for physical property damage or damages caused by fire, as opposed to economic losses, such as business interruption caused by a loss of power.
The claims professional should be mindful of photographing and documenting evidence of burn patterns around equipment such as transformers, power lines or meters, as well as noting the presence of foreign matter or conductive debris, such as corrosion or carbon tracking.
6. APPLICABILITY OF LIABILITY INSURANCE COVERAGE
Many liability insurance policies do not cover claims against insureds for completed operations or for product failures unaccompanied by damage to other property. In some situations, a responsible party may have a claim against its broker or agent for negligently failing to broker a policy with appropriate coverages. In such situations, the responsible party may assign its right of action against the broker or agent to the prospective plaintiff in exchange for an agreement not to pursue recovery from the defendant’s assets.
Case study: Subrogation and Insurer Intervention in Construction Defect Case Involving Water and Mold
By paying a portion of its insureds claims for property damage to their house, State Farm Insurance obtained partial subrogation rights under the homeowners policy entitling it to intervene in a construction defect lawsuit that the homeowner brought against third parties who they alleged caused the loss.
The homeowners ("Hodges") submitted a claim in the amount of $1,699,680 to State Farm under its homeowners policy for water and mold damage to their house. They alleged the damage was caused by the negligence of third parties. State Farm denied the claim for mold damage but paid $150,000 for water damages.
Homeowner Suit against Third Parties
The Hodges subsequently filed a construction defect suit against the former owner, the developer, the general contractor, and a subcontractor who had constructed the house. They alleged the defendants caused the water and mold damage by performing defective work, violating building codes, failing to comply with plans and specifications, using unauthorized or unqualified subcontractors, failing to repair defective work, conducting inadequate repair work, and negligently supervising construction of the house.
Homeowner Suit against State Farm
A couple months after filing that lawsuit, the Hodges filed a separate lawsuit against State Farm, in the same county court in California. This suit alleged that State Farm acted in bad faith in denying coverage. State Farm filed a motion with the court to consolidate the construction defect case and the bad faith case. The trial court denied the motion.
State Farm Moves to Intervene in the Third Party Suit
State Farm then filed a motion for leave to intervene in the construction defect case to file a subrogation complaint to recover what it had paid its insured homeowner as a result of the alleged negligence of those responsible for the construction defects. The trial court in the third-party suit ruled against State Farm and denied the motion to intervene in the suit.
As a result of the adverse outcomes of both trial courts against State Farm's motions, State Farm would be unable to participate in the underlying actions involving those that were allegedly responsible for the loss to the homeowner—which loss State Farm had already partially paid, and which loss State Farm might potentially be required to pay additional amounts.
State Farm Appeals
State Farm appealed the denial of its motion to intervene. The appellate court concluded that as a partially subrogated insurer, State Farm had an interest "relating to the property or transaction" that was the subject of the construction defect lawsuit. The court explained that:
·         Under the doctrine of subrogation, when an insurer pays money to its insured for a loss caused by a third party, the insurer succeeds to its insured's rights against the third party in the amount the insurer paid.
The court also stated that, "Upon subrogation, the insurer steps into the shoes of its insured." An insurer has a direct pecuniary interest in the outcome of the litigation between the insured and the responsible third party, says the court, and in this case "State Farm has a direct pecuniary interest in the Hodges' action against the allegedly responsible third parties."
The appellate court concluded that intervention in the construction defect case is necessary because the outcome of that case could impair or impede State Farm's ability to protect its subrogation rights. The safest course to protect the interests of an insurance company is to seek intervention in the insured's lawsuit against the legally responsible third party. The court pointed out that there are two theoretical alternatives to intervention. These are for the insurance company to (1) file a separate lawsuit against the responsible third party, or (2) to recoup payments directly out of the insured's recovery from the responsible third party. But both of these alternatives would be inadequate and inconsistent with the purpose of intervention.
Absent intervention, "the insurer is to a large extent at the mercy of the insured's efforts and success in recovering from the responsible third party." If State Farm had to rely only on recoupment from its insured, "State Farm would not be able to assert its rights of recoupment against the Hodges until they fully recovered from the construction defect lawsuit defendants, and then only to the extent the Hodges recovered more than the amount of their insured loss." This could be particularly problematic because as the court noted, "the Hodges' interests are not necessarily aligned with State Farm's. The Hodges would have little incentive to invest time, effort, and fees pursuing defendants to recovery for covered claims."
Indeed, State Farm's interests would potentially be inadequately represented by the parties in the construction defect case because, as noted by the court, the Hodges and State Farm have opposing interests as concerns proving whether the losses resulted from mold damages or from water damages. State Farm's interests are not adequately represented by the Hodges because they have an incentive to advance their interests in the construction defect lawsuit at the expense of protecting State Farm's subrogation rights. For these reasons, the appellate court held that State Farm was entitled to intervene in the case and, therefore, reversed the trial court. Douglas M. Hodge v. Kirkpatrick Development, Inc. (Cal. 4th App. Div., G034361).
Comment
State Farm was found, pursuant to the terms of the insurance policy as well as by law, to be entitled to intervene in the construction defect case. The subrogation paragraph in Hodges policy stated in relevant part:
·         An insured may waive in writing before a loss all rights of recovery against any person. If not waived, we may require an assignment of rights of recovery for a loss to the extent that payment is made by us.
In this case, subrogation rights had not been waived before the loss in question.  State Farm, therefore, had a right under the terms and conditions of the policy to participate in the lawsuits to protect its right of subrogation. State Farm needed to exercise its right in this matter to assure that the strongest case was made against the construction defect defendants. It had an interest in assuring that the facts and evidence were fairly presented to determine who and what caused the damages. In particular, it was important to determine to what extent losses resulted from mold versus water damage.
As with the standard insurance policies, this policy included a condition requiring that the Insured "do nothing after a loss to prejudice State Farm's subrogation rights." If the Hodges had proceeded in the construction defect litigation without State Farm's participation (as they desired to do), and had they obtained a result that State Farm reasonably believed was designed to harm State Farm's interests, State Farm would have been legally entitled under the policy to bring a law suit against the Hodges for impairment of its subrogation rights.
It would appear that the interests of all parties were best served by having State Farm intervene in the underlying construction defect action. The court in this case reached the correct decision. It provided a well-reasoned opinion that will serve as a valuable educational tool for others contemplating similar issues concerning subrogation and the right to insurance company intervention in litigation.

SUBROGATION SERVICES AT METROPOLITAN
METROPOLITAN has broad experience handling subrogation claims arising from water, fires, explosions, construction defects, product failures, energy and oil release claims, and boiler and machinery failures.  Our cases range from highly complex commercial losses to smaller scale business and personal lines claims.  Claims we handle include:


  • alarm/security
  • boiler
  • building, roof, crane collapses
  • building system failures
  • chemical explosions
  • construction defects
  • earth movement
  • electrical failures
  • employee dishonesty
  • environmental
  • explosions
  • fires
  • floods


  • geotechnical failures
  • grill malfunctions
  • industrial accidents
  • industrial equipment failures
  • machinery and equipment failures
  • mechanical failures
  • mold
  • natural gas explosions
  • product liability
  • sewer back-up
  • steam line failures
  • spontaneous-combustion fires
  • spread fires
We routinely involve our teams of origin and cause investigators; civil, structural, geotechnical, electrical, mechanical, metallurgical, materials, and automotive engineers; combustion scientists; fire protection specialists; certified fraud examiners; accountants; law enforcement; and coverage counsel in the underlying claim to analyze and determine the causes of losses and accidents.  We work with outside or insurer counsel to ensure thorough analysis, proper evaluation of losses, and to exhaust and/or eliminate alternative theories.  We, along with the team of lawyers, develop non-destructive and destructive testing protocols, coordinate transfer of evidence and preservation of evidence.
Metropolitan Engineering, Consulting & Forensics (MECF)
Providing Competent, Expert and Objective Investigative Engineering and Consulting Services
P.O. Box 520
Tenafly, NJ 07670-0520
Tel.: (973) 897-8162
Fax: (973) 810-0440
E-mail: metroforensics@gmail.com
Web pages: https://sites.google.com/site/metropolitanforensics/
https://sites.google.com/site/metropolitanenvironmental/

http://metroforensics.blogspot.com/

We are happy to announce the launch of our twitter account. Please make sure to follow us at @MetropForensics or @metroforensics1
Metropolitan appreciates your business.
Feel free to recommend our services to your friends and colleagues.