MEC&F Expert Engineers

Sunday, November 9, 2014

WHAT ARE THE CONNECTIONS BETWEEN MERCURY, UV AND PHENOL EMISSIONS AND COMPACT FLUORESCENT LIGHT LAMPS (CFL)?



WHAT ARE THE CONNECTIONS BETWEEN MERCURY, UV AND PHENOL EMISSIONS AND COMPACT FLUORESCENT LIGHT LAMPS (CFL)?


What are compact fluorescent lamps (CFLs)?

CFLs are a type of fluorescent lamp. Many models of CFLs are available that are designed to replace traditional incandescent bulbs. The compact size of these CFLs allows them to fit into many existing incandescent light fixtures, including table and floor lamps commonly found in households. CFLs are very energy efficient, using approximately one quarter of the energy compared to traditional incandescent bulbs. CFLs also have a very long lifespan, typically 6000- 15,000 hours compared to the 750-1,000 hours for a normal incandescent bulb.




Fluorescent lamps, including CFLs, are electronic products subject to Section 532 of the Food, Drug, and Cosmetic Act. Section 532 of the Act authorizes FDA to establish and carry out an electronic product radiation control program designed to protect the public health and safety from radiation that may be emitted from electronic products, such as the UV that may be emitted from CFLs.

Although FDA regulates CFLs under the Code of Federal Regulations (CFR) 21 Part 1000, there are currently no specific standards or annual reporting requirements for CFLs. Manufacturers of CFLs are subject to CFR 21 part 1002.20, which requires CFL manufacturers to report accidental radiation incidents should any occur. In addition, CFR part 1003.10 requires manufacturers to notify FDA in the event of a product defect or failure which would result in an accidental exposure incident.

The vast majority of products of concern to the FDA are capable of emitting significant levels of radiation, such as X-ray equipment or skin tanning lamps but CFLs do not fall into this area.






Why use CFLs if they contain mercury?
Small amounts of mercury can be released into the environment when CFLs break, or if they are improperly disposed of at the end of their useful lives. Despite these emissions, the use of CFLs actually helps reduce total mercury emissions in the U.S. because of their significant energy savings.  Using energy-saving CFLs reduces demand for electricity, which in turn reduces the amount of coal burned by power plants, which reduces emissions of mercury when the coal is burned.
Saving energy helps you save money on utility bills.  You can learn more about how how CFLs work, and CFLs and mercury, from EnergyStar.gov.




Learn More about Mercury and CFLs
1. Using CFLs (and other fluorescent bulbs) reduces the amount of mercury released into the environment

  • Mercury is found in many rocks including coal. When coal is burned at a utility power plant to produce electricity, mercury is released into the environment.
  • In the U.S., burning coal at power plants results in about half of all mercury emissions from man-made sources (source: Section 2.6 of the 2011 National Emissions Inventory, version 1 (November 2013) of the Technical Support Document (PDF)).
  • Using energy-efficient CFLs reduces demand for power, which in turn reduces the amount of coal burned by power plants and the amount of mercury emitted when coal is burned.

 


 

2. CFLs contain very small amounts of mercury

  • Mercury, an essential part of CFLs, allows a bulb to be an efficient light source.
  • On average, CFLs contain about four milligrams of mercury sealed within the glass tubing. By comparison, older thermometers contain about 500 milligrams of mercury – an amount equal to the mercury in over 100 CFLs.
  • Manufacturers of fluorescent lighting products are working to reduce the amount of mercury content in CFLs.
  • No mercury is released when the bulbs are intact (i.e., not broken) or in use, but CFLs can release mercury vapor when broken.

Do CFLs emit UV?

All fluorescent lamps emit some UV. Typical fluorescent lamps, including CFLs, which consumers would encounter, emit very low levels of UV. In order to measure any UV radiation from these lamps, very sensitive measuring equipment must be used.





What is the wavelength range of the light radiation that is emitted by CFLs?

Since CFLs are designed to provide general illumination, the majority of the light emitted by CFLs is localized to the visible region of the spectrum (approximately 400-700 nm in wavelength). In addition, typical CFLs emit a small amount of UVB (280-315 nm), UVA (315-400 nm) and infrared (> 700 nm) radiation.




How close can we safely get to an operating CFL?
Unless you are one of the few individuals who have a medical condition (such as some forms of Lupus) that makes you particularly sensitive to either UV or even visible light, you should be able to use these lamps at the same distance as you would use traditional incandescent lamps. However, a recent study from the United Kingdom Health Protection Agency has found that there are measureable levels of UV from single envelope CFLs when used at distances closer than 1 foot. As a precaution, it is recommended that these types of CFLs not be used at distances closer than 1 foot, for more than one hour per day.






How do I know if I am particularly sensitive to either UV or visible light?

Only your physician can make such a diagnosis. The vast majority of people do not suffer from such UV or visible light sensitivities.






Are there precautions I can take to reduce the small levels of UV from CFLs still further if I should wish to do so?

The glass used in CFLs already provides a UV filtering effect. In addition, any additional glass, or plastic, or fabric used in lighting fixtures that is between you and the CFL will further reduce the already low levels to still lower levels since these materials act as additional UV filters. Increasing the distance between you and any radiation source, including CFLs, will also reduce the small level to a lower level.

However, if you still wish to take additional steps then you might wish to purchase the type of CFL that has an additional glass or plastic cover that enclosed the CFL to make it appear more like a traditional incandescent lamp. These covers provide an additional reduction of the low level of UV to a lower level.



Any other safety concerns? I have heard CFLs contain mercury. Should I be concerned?
Like traditional tube-style fluorescent lamps, CFLs contain a small amount of mercury. It is the use of this small amount of mercury that allows any fluorescent lamp to produce visible illumination at much higher efficiency levels than incandescent lighting. Typical household CFLs contain less than 5 mg of mercury, which is a sphere about the size of the tip of a pen. CFLs do not emit mercury as they operate. The only way mercury could be emitted from a CFL would be if the outer glass tubing that contains the mercury were to break.
Care should be taken not to break a CFL. If you break one, you should carefully clean up the entire residue according to EPA instructions that you can find at http://www.epa.gov/mercury/spills/index.htm
What about other potential adverse health effects from CFLs? I have seen some claims that CFLs cause headaches in some people. Is this true?
The vast majority of CFL users, both in households and in commercial buildings, report no issues regarding CFL usage, including headaches. There are some anecdotal reports, however, and, although there is yet no research to directly explain any plausible causative mechanism, it may be possible that some people are susceptible to such headache effects just as some people claim to be annoyed by normal fluorescent lighting. However, the overwhelming numbers of people that use CFLs report no such negative effects.






Breakage
Fluorescent lamps produce several hazards if shattered. Depending on the type, there may be a partial vacuum or the light bulb may be under pressure. Shattering the glass can cause shrapnel injuries, along with the release of mercury and other unhealthy compounds.
The biggest immediate injury danger from a damaged lamp is from the phosphor-coated glass. If cut with fluorescent lamp glass, any phosphor that goes in the wound is likely to stop blood clotting and can interfere with curing. Such mishaps should be handled seriously and immediate medical assistance should be obtained for people or domestic pets that are cut. Medical employees ought to be notified that the injuries were caused by a damaged fluorescent lamp, and that mercury was present.
Reference: http://www.parkinsonarchitecture.com/?p=219
Fluorescent Lighting Dangers – Why LED Bulbs Will Be The Better Alternative



PHENOL AND STYRENE EMISSIONS
Toxic mercury from broken bulbs might not be the only danger posed by CFL lamps. During tests last year at Berlin's Ala Laboratory, scientists discovered that various carcinogenic chemicals and toxins, including phenol, naphthalene and styrene, are released when CFL are switched on.
Environmental experts in Britain have downplayed the findings, insisting that CFLs are not a danger to the public and that more studies are needed to back up the German research.
But Peter Braun, who carried out the tests at the lab, claims that CFL lamps emit poisonous vapors when turned on and “should not be used in unventilated areas and definitely not in the proximity of the head.”
This report comes on the heals of research by Israel’s Haifa University suggesting that the CFL’s bluer light emissions, which closely mimic daylight, might interfere with the production of the hormone melatonin, contributing to higher rates of breast cancer.
In addition, the Migraine Action Association is warning that CFLs could trigger migraine headaches, “and skin care specialists have claimed that their intense light could exacerbate a range of existing skin problems,” according to a report in London’s Daily Telegraph.



Metropolitan Engineering, Consulting & Forensics (MECF)

Providing Competent, Expert and Objective Investigative Engineering and Consulting Services
P.O. Box 520
Tenafly, NJ 07670-0520
Tel.: (973) 897-8162
Fax: (973) 810-0440
E-mail: metroforensics@gmail.com
Web pages: https://sites.google.com/site/metropolitanforensics/
https://sites.google.com/site/metropolitanenvironmental/
We are happy to announce the launch of our twitter account. Please make sure to follow us at @MetropForensics or @metroforensics1
Metropolitan appreciates your business.
Feel free to recommend our services to your friends and colleagues.

To unsubscribe from future technical blogs and announcements, please reply to this email with the word “unsubscribe” in the subject line.


Saturday, November 8, 2014

Novel Activation Technologies for Sodium Persulfate In Situ Chemical Oxidation



Novel Activation Technologies for Sodium Persulfate In Situ Chemical Oxidation

Introduction
Persulfates (specifically dipersulfates) are strong oxidants that have been widely used in many industries for initiating emulsion polymerization reactions, clarifying swimming pools, hair bleaching, micro-etching of copper printed circuit boards, and TOC analysis. In the last few years there has been increasing interest in sodium persulfate as an oxidant for the destruction of a broad range of soil and groundwater contaminants. Persulfates are typically manufactured as the sodium, potassium, and ammonium salts. The sodium form is the most commonly used for environmental applications. 

The persulfate anion is the most powerful oxidant of the peroxygen family of compounds and one of the strongest oxidants used in remediation. The standard oxidation – reduction potential for the reaction 



is 2.1 V, as compared to 1.8 V for hydrogen peroxide (H2O2) and 1.4 V for the peroxymonosulfate anion (HSO5-). This potential is higher than the redox potential for the permanganate anion (MnO4-) at 1.7 V, but slightly lower than that of ozone at 2.2 V. 

In addition to direct oxidation, sodium persulfate can be induced to form sulfate radicals, thereby providing free radical reaction mechanisms similar to the hydroxyl radical pathways generated by Fenton’s chemistry. The generation of sulfate radicals is 





The sulfate radical is one of the strongest aqueous oxidizing species with a redox potential estimated to be 2.6 V, similar to that of the hydroxyl radical, 2.7 V.
In addition to its oxidizing strength, persulfate and sulfate radical oxidation has several advantages over other oxidant systems. First, it is kinetically fast. Second, the sulfate radical is more stable than the hydroxyl radical and thus able to transport greater distances in the sub-surface. Third, persulfate has less affinity for natural soil organics than does the permanganate ion (Brown 2003) and is thus more efficient in high organic soils. These attributes combine to make persulfate a viable option for the chemical oxidation of a broad range of contaminants. 

Conventional Persulfate Activation 
In the early 1960’s, a significant body of work examined the kinetics and mechanisms associated with persulfate oxidation (House, 1962 and Haikola, 1963). While the persulfate anion by itself was found to be a strong oxidizer, it’s reaction rates are kinetically slow for the more recalcitrant contaminants, such as trichloroethylene. However, the kinetics of persulfate oxidation can be significantly enhanced by the generation of sulfate radicals. 

Sulfate radical initiation (Equation 2) can be achieved through the application of heat, transition metal catalysts or UV radiation. These processes are reviewed in several references (House, 1962; Behrman, 1980; Balazs, 2000). With transition metal activation, Balazs points out that while the mechanism is dependent on catalyst type, organic substrate and oxidant concentration, the rate equation can be generally stated as: 





where ½ < x < 3/2 and 0 < y < 3/2. This suggests that the reaction rate is independent of the contaminant loading. Several recent patents have specifically disclosed the activation of persulfate for the oxidation of organic contaminants by either heat or transition metals. Pugh (1999) discusses both metal catalysis and heat activation, at temperatures above 200C, to oxidize organic contaminants. Hoag (2000, 2002) discusses divalent metal catalysis and the application of heat in the range of 40 to 990C to oxidize VOCs. This body of literature basically leads one to conclude that the effective use of persulfate for environmental applications necessitates the use of either heat activation of the addition of iron II. 

In the laboratory, heat-activated persulfate has been demonstrated in aqueous systems to be applicable to a wide range of contaminants. The activation temperature required varies by compound. Table 1 lists the oxidation of various compounds as a function of temperature. At 45oC and above all the compounds tested were oxidized. Bruell (2001) has shown that heat-catalyzed persulfate oxidation of organics in a soil environment requires higher temperatures than in aqueous systems. 

For activation by transition metal catalysis, ferrous iron (Fe+2) is the most common and readily available activator, with common forms being ferrous sulfate (FeSO4) and ferrous chloride (FeCl2). Generally, 100 to 250 mg / L of iron is required to effectively activate persulfate. Additions of ferrous iron in excess, greater than 750 mg / L, can lead to the rapid decomposition of persulfate and a lossin remediation performance. If significant amounts of reduced metals are available in the subsurface, addition of metal catalysts may not be necessary to catalyze the persulfate. Divalent iron activated persulfate effectively oxidizes many of the compounds susceptible to the heat-activated persulfate, including BTEX, chlorobenzene, dichlorobenze, DCE, TCE, and PCE. However, its effectiveness against chlorinated ethanes, such as TCA, and chlorinated methanes, such as chloroform, is limited. 


 

While heat and iron II activation of persulfate are effective in bench scale oxidation studies, they both have limitations for field application. Heat activation requires installation of a parallel heating system to heat the aquifer matrix to the desired temperature. This entails both capital expenditures as well as additional operating expense. The options for in situ heating include steam or hot air injection, electrical resistance (joule) heating, or radio frequency heating. Generally heating is best applied for source treatment where the target area is limited. In situ heating, with an external heating source, is impractical for treating large groundwater plumes. 

The problem with the use of iron II as an activator is its transportability. Iron II is eventually oxidized by the persulfate to iron III, which, at a pH above 4, is insoluble. The net reaction is: 





Meyers (Meyers, 2002) discussed the affect of the precipitation of iron on the loss of persulfate activation in field applications. As an example, in a pilot treatment test of TCE with persulfate, a persulfate and iron mixture (10% sodium persulfate and 174 mg/L of available Fe+2) was injected into a sandy silt. Nine days after the injection, a monitoring point 1.5 M down-gradient of the injection point was sampled, and the iron concentration was found to be 0.3 mg/L, and the TCE concentration was 9.3 mg/L. Groundwater samples from the monitoring point were collected and re-dosed with either iron alone or with persulfate without additional iron. After 7 days the re-dosed samples were reanalyzed for TCE. The results are shown in Table 2. Greater reduction in TCE levels was achieved when additional Fe+2 was added, as compared to when only additional persulfate was added, suggesting a lack of available catalyst, and not oxidant, in the subsurface at the down-gradient monitoring point. 







Novel Activation Technologies
Practical constraints in sulfate radical formation by heating or addition of ferrous iron indicate a need for improved persulfate activation systems. Such technologies should: 

  • be transportable in a groundwater system
  • increase the reactivity of persulfate with a broad range of organic contaminants
  • be easy to apply in a variety of subsurface conditions.



Several new persulfate activation systems have recently been developed (FMC - ERM, 2002; FMC - Orin, 2003) that address these issues. A few of these technologies use non- metal routes to generate sulfate radicals. The following is a discussion of these novel activators.


A. Chelated Metal Catalysts
Chelated metal catalysts are complexes of transition metals bound to strong chelating agents. Examples of chelating agents include: ethylenediaminetetraacetic acid (EDTA), citrate, polyphosphate, glycolic acid, catechol, nitrotriacetic acid (NTA), Tetrahydroquinine (THQ) and others in this class of materials. Previous work (Pignatello, 1992) demonstrated the benefit of chelated iron complexes to activate hydrogen peroxide for the destruction of complex pesticides. Chelated trivalent iron (Fe+3), in addition to Fe+2, was found to have excellent oxidation performance. 


Laboratory tests were conducted to test the efficacy of chelated iron catalysts for persulfate activation utilizing several different iron – chelant complexes. The best performing complex, Fe(III) – EDTA will be highlighted for discussion purposes. All samples were prepared as aqueous solutions in VOA bottles with zero headspace. A standard contaminant mixture was used: twenty-eight different VOCs were dissolved in DI water to attain individual VOC concentrations of 10-20 mg/L. The Fe-EDTA complex was generated by reacting equimolar concentrations of ferric chloride and EDTA. The Fe -EDTA complex was dosed to provide 550 mg / L of available iron to the solution. An oxidant dosage level of 10 % sodium persulfate was used. Samples were taken at time zero, and at 7, 14 and 21 days and analyzed via GC-MS. All studies were conducted at room temperature and ambient pH. 


The 21-day results are shown in Table 3, which compares persulfate alone and persulfate with: iron II (unchelated), Fe(III) (unchelated), and Fe(III)-EDTA. A DI water control was also run. The table displays the results for different classes of contaminants. Several observations can be made from the data. First, none of the persulfate / iron catalysts are effective with the chloroethanes or chloromethanes. Second, all persulfate solutions resulted in a low pH. Third, Fe(II) was the most effective catalyst. The second best performing catalyst was the Fe-EDTA complex. Fourth, BTEX oxidation was effective with persulfate alone. And fifth, Fe(III), at a low pH, is a moderately effective catalyst. It should be noted that the results in Table 3 are at a pH of 2, where metal solubility and activity is not an issue 



Under the neutral pH conditions that may be found in the field, chelating the transition metal catalyst provides protection from hydration and subsequent precipitation (see Eq. 4). Table 4 shows the results for different iron catalysts with persulfate at a controlled pH of 7-8. The experimental conditions were similar to those used to generate Table 3, except: 1) a commercial Fe (III) -EDTA (Aldrich) was used with the dosing level at 100 mg/L iron, and 2) the persulfate concentration was 2.5% (instead of 10%). As can be seen from Table 4, at a pH of 7 - 8, only the Fe-EDTA catalyst with persulfate was effective; whereas the un-chelated iron catalysts had reduced activity. 





The solubility and availability of the transition metal catalysts are critical factors in the activation of persulfate. Chelation is an effective means of maintaining metal activity at neutral or alkaline groundwater conditions. 


B. Dual Oxidant System: Sodium Persulfate & Hydrogen Peroxide 

Hydrogen peroxide technology, known as Fenton’s reagent, has been widely applied in treating groundwater contaminants with varying results. In general, it is highly reactive and is able to oxidize a wide range of contaminants. However, the limitation of peroxide is its stability in some soil matrixes, where it rapidly decomposes, limiting its transport and effectiveness. A dual oxidant system (FMC - Orin, 2003) utilizing hydrogen peroxide and sodium persulfate has been developed that combines the reactivity of peroxide in the reduction of compounds of concern with the enhanced stability of persulfate. It is hypothesized that hydrogen peroxide and persulfate may have several synergistic attributes. First, hydroxyl radicals can initiate persulfate radical formation. Similarly, sulfate radicals can stimulate formation of hydroxyl radicals. Secondly, hydrogen peroxide may react with a significant portion of the more reactive contaminants, allowing the sulfate radicals to destroy the more recalcitrant compounds of concern. Finally, a combination of peroxide and sulfate radicals may provide a multi-radical attack mechanism, yielding either a higher efficiency in destroying contaminants, or allowing for recalcitrant compounds to be more readily degraded. 

Initial laboratory testing by Orin RT (FMC - Orin, 2003) was performed by adding chlorinated solvents to an aqueous solution at room temperature. Two grams of sodium persulfate and 8 mL of 12.5% hydrogen peroxide were added per 100 grams of contaminated solution. Samples were taken on Day 8 and analyzed by GC-MS. Table 5 displays the results from the study. Significant reductions were measured not only for chlorinated ethenes, but chlorinated ethanes as well. 



A second laboratory study was run using soils from an MGP site. A slurry was made using 400 g of processed soil and 1.08 L of distilled water. Sodium persulfate was then added to a concentration of 11.5 g/L and allowed to mix. 120 mL of 50% peroxide was then added. The slurry was then analyzed via GC-MS. The results are pictured in Figure 1. The VOCs present were BTEX and styrene. The SVOCs were 3 to 5 ring PAHs. Dicylcopentadiene (DCPD) was present as the major constituent. As can be seen from Figure 1, the combined peroxide-persulfate system was effective against all of these contaminants. 




The combined peroxide-persulfate reaction system appears to have a broad range of applicability. It not only oxidizes compounds generally amenable to persulfate oxidation, but also oxidizes compounds not readily oxidized by conventional persulfate technology. 

The combined peroxide-persulfate reaction system appears to have a broad range of applicability. It not only oxidizes compounds generally amenable to persulfate oxidation, but also oxidizes compounds not readily oxidized by conventional persulfate technology. 

D. Alkaline Persulfate 

Persulfate is known to be highly reactive at low pH (<3), but it is also highly reactive at pH’s greater than 10. It should thus be possible to “activate” persulfate by increasing the pH to high values. Initial laboratory testing indicated the persulfate oxidation of contaminants was not just a matter of high pH, but of the buffering capacity as well (mole ratio of pH modifier to persulfate). 

Studies were conducted in VOA vials with zero headspace. While a variety of pH modifiers were observed to activate persulfate, KOH will be used for discussion. Samples were prepared by adding persulfate at a concentration of 25 g/L and KOH to achieve mole ratios of 0.2, 0.4, 0.5 and 0.8 KOH : persulfate. The samples were analyzed after 7 days by GC-MS. A control with no persulfate or KOH was also run. No other catalysts were added to the samples. The activation of persulfate that was observed is solely due to the added base. The results of these studies are pictured in Figure 2. The data are grouped by class of contaminant. 




Several observations can be made from these results. First persulfate reactivity increases with increasing levels of KOH. Second, there appears to be a threshold effect in the oxidation of some chlorinated VOCs. The mole ratio needs to be 0.4 or above for the persulfate to effectively react with the recalcitrant chlorinated VOCs (ethanes and methanes). The effect of the amount of KOH on the oxidation of BTEX and oxygenates (MTBE, TBA, 1,4-dioxane) is more gradual. The amount oxidized increases with increasing KOH. 

Table 6 lists the pH observed at 7 and 14 days for the different mole ratios of KOH and persulfate. The pH appears to have a breakpoint similar to that observed for the reactivity. A mole ratio of 0.4 or above is needed to achieve a pH above 10.0. 



An interesting result for this study is the effect of the alkaline pH on historically difficult to destroy compounds, such as chlorinated ethanes and methanes. Table 7 displays the 14 day results from the study for a selection of compounds for two different KOH : persulfate mole ratios. In most cases, there was complete destruction of these compounds 





A number of conclusions can be drawn from these studies. First, alkaline persulfate has a broad reactivity. Second, the alkaline activation of persulfate appears to be possible with a number of different bases. Each base may have a different optimal ratio and/or breakpoint. Third, in applying the alkaline-persulfate activator technology it is important to add sufficient base (excess buffering capacity). The quantity of base needs to take into account any acidity in the soil. Fourth, there are reaction pathways for persulfate that are not currently well understood and can potentially be further optimized. The reaction of persulfate under basic conditions is a novel technology deserving further study. 

Summary
Persulfate oxidation chemistry is an emerging technology for the in situ chemical oxidation of chlorinated and non-chlorinated organics. Activation of persulfate to form sulfate radicals yields a very potent tool for the remediation of a wide variety of contaminants, including chlorinated solvents (ethenes, ethanes and methanes), BTEX, MTBE, 1,4-dioxane, PCB’s and polyaromatic hydrocarbons. 





There now exists a variety of chemistries from which to choose to catalyze the formation of sulfate radicals. Choosing which activator system to use is key to maximizing the efficacy of persulfate oxidation. Figure 3 provides a logic-flow for assessing the different activator systems. There are three levels of persulfate activators that can be used. These include “Mild Oxidation,” in which persulfate alone is used. This may be appropriate for BTEX sites. If MTBE is present, then the “Strong Oxidation” system, which is persulfate activated with Fe-EDTA, is appropriate. This “Strong Oxidation” system is also appropriate for sites with only chlorinated ethenes (PCE, TCE, DCE) or chloro-benzenes. If there are chlorinated ethanes or methanes present that need treatment, then the “Aggressive Oxidation” systems should be evaluated. These include the alkaline-persulfate, combined peroxide and persulfate, and heated persulfate. These aggressive activation chemistries may be applied also for BTEX and chlorinated ethene sites if faster remediation is desired, or if there is a high contaminant load.
Proper evaluation of the site conditions is also needed for the effective application of the appropriate persulfate technology. Site geology, hydrogeology, soil properties, soil oxidant demand, and the remedial goals are all key factors to evaluate. Persulfate technology is not a “one-size-fits-all” technology. There is a rich and varied chemistry that can be brought to bear on a wide variety of contaminant problems. 

References
Balazs, G.B., J.F. Cooper, P.R. Lewis and G.M. Adamson. Emerging Technologies in Hazardous Waste Management 8, ed. Tedder and Pohland, Kluwer Academic / Plenum Publishers, New York, 2000.
Behrman, E.J. and J.O. Edwards. Reviews in Inorganic Chemistry, 2, p 179 (1980) Brown, R.A., D. Robinson and G. Skladany. “Response to Naturally Occurring Organic Material: Permanganate versus Persulfate”, ConSoil 2003, Ghent Belgium, (2003) Bruell, C. J. “Kinetics of Thermally Activated Persulfate Oxidation of Trichloroethylene (TCE) and 1,1,1- Trichloroethane (TCA),” The First International Conference on Oxidation and Reduction Technologies for In-Situ Treatment of Soil and Groundwater, Niagara Falls, Ontario, Canada, June 25-29, 2001
Elmendorf, C., F. Sessa. Poster at the 4th Annual Batelle Conference On the Remediation of hlorinated and Recalcitrant Compounds, Panther Technologies and FMC Corporation (2004)
FMC Corporation and Environmental Resources Management, patent pending technology (2002) FMC Corporation and Orin RT, patent pending technology (2003)