Taxiway Overflight Air Canada Flight 759 Airbus A320-211, C-FKCK, San Francisco, California July 7, 2017: The probable cause of this incident was the flight crew’s misidentification of taxiway C as the intended landing runway

Taxiway Overflight Air Canada Flight 759 Airbus A320-211, C-FKCK, San Francisco, California July 7, 2017

Executive Summary

​On July 7, 2017, about 2356 Pacific daylight time (PDT), Air Canada flight 759, an Airbus A320-211, Canadian registration C-FKCK, was cleared to land on runway 28R at San Francisco International Airport (SFO), San Francisco, California, but instead lined up with parallel taxiway C. Four air carrier airplanes (a Boeing 787, an Airbus A340, another Boeing 787, and a Boeing 737) were on taxiway C awaiting clearance to take off from runway 28R. The incident airplane descended to an altitude of 100 ft above ground level and overflew the first airplane on the taxiway. The incident flight crew initiated a go-around, and the airplane reached a minimum altitude of about 60 ft and overflew the second airplane on the taxiway before starting to climb. None of the 5 flight crewmembers and 135 passengers aboard the incident airplane were injured, and the incident airplane was not damaged. The incident flight was operated by Air Canada under Title 14 Code of Federal Regulations (CFR) Part 129 as an international scheduled passenger flight from Toronto/Lester B. Pearson International Airport, Toronto, Canada. An instrument flight rules flight plan had been filed. Night visual meteorological conditions prevailed at the time of the incident.

Probable Cause

​The National Transportation Safety Board determines that the probable cause of this incident was the flight crew’s misidentification of taxiway C as the intended landing runway, which resulted from the crewmembers’ lack of awareness of the parallel runway closure due to their ineffective review of notice to airmen (NOTAM) information before the flight and during the approach briefing. Contributing to the incident were (1) the flight crew’s failure to tune the instrument landing system frequency for backup lateral guidance, expectation bias, fatigue due to circadian disruption and length of continued wakefulness, and breakdowns in crew resource management and (2) Air Canada’s ineffective presentation of approach procedure and NOTAM information.

The Deadly Over-pressure of a Columbia Gas of Massachusetts (Columbia gas, a susidiary of NiSource) Low-pressure Natural Gas Distribution System damaged 131 structures, including at least 5 homes that were destroyed in the city of Lawrence and the towns of Andover and North Andover.

Preliminary Report Pipeline: Over-pressure of a Columbia Gas of Massachusetts Low-pressure Natural Gas Distribution System

Executive Summary

The information in this report is preliminary and will be either supplemented or corrected during the course of the investigation.
On September 13, 2018, about 4:00 p.m. eastern daylight time, a series of explosions and fires occurred after high-pressure natural gas was released into a low-pressure gas distribution system in the northeast region of the Merrimack Valley in the state of Massachusetts.1 (See figure 1.) The distribution system was owned and operated by Columbia Gas of Massachusetts (Columbia Gas), a subsidiary of NiSource. The system over-pressure damaged 131 structures, including at least 5 homes that were destroyed in the city of Lawrence and the towns of Andover and North Andover. Most of the damage was a result of structure fires ignited by gas-fueled appliances. Several structures were destroyed by natural gas explosions. One person was killed and at least 21 individuals, including 2 firefighters, were transported to the hospital. Seven other firefighters received minor injuries.
Map of area impacted by accident depicting structures that were damaged.Figure 1. Area impacted by accident depicting structures that were damaged.

Fire departments from the three municipalities were dispatched to address the multiple fires and explosions. (See figures 2 and 3.) First responders initiated the state’s fire mobilization plan, that included mutual aid from other districts in Massachusetts, New Hampshire, and Maine.

Aerial view of damaged home where a fatality occurred after the chimney collapsed. 
 Figure 2. Aerial view of damaged home where a fatality occurred after the chimney collapsed on vehicle in the driveway.

Aerial view of burned-out home impacted by the event.Figure 3. Aerial view of burned-out home impacted by the event.
 
Emergency responders asked residents to evacuate from the impacted area to four evacuation centers. At the request of emergency management officials, National Grid shut down electrical power in the affected area to remove a source of ignition. Nearby roads were closed, and freight and passenger railroad operations were suspended. Columbia Gas also shut down the low-pressure, natural gas distribution system.[2]
The cast-iron, low-pressure distribution system was installed in the early 1900s and had been partially improved with both steel and plastic pipe upgrades since the 1950s. The low-pressure distribution system in the affected area relied on 14 regulator stations to control gas at the required pressure into structures serviced by the system, unlike high-pressure gas distribution systems that place an individual regulator to reduce pressure at each customer service.[3] Each of the regulator stations reduced the pressure from about 75-pounds per square inch gauge (psig) natural gas main pipeline to 12 inches of water column (about 0.5 psig) for delivery to customers.

Prior to the over-pressure event, a Columbia Gas-contracted work crew, which included a Columbia Gas inspector, was performing a Columbia Gas-designed and approved pipe-replacement project at a nearby intersection (South Union Street and Salem Street) in South Lawrence. The contracted crew was working on a tie-in project of a new plastic distribution main and the abandonment of a cast-iron distribution main. The distribution main that was abandoned still had the regulator sensing lines that were used to detect pressure in the distribution system and provide input to the regulators to control the system pressure. Once the contractor crews disconnected the distribution main that was going to be abandoned, the section containing the sensing lines began losing pressure.
As the pressure in the abandoned distribution main dropped about 0.25 inches of water column (about 0.01 psig), the regulators responded by opening further, increasing pressure in the distribution system. Since the regulators no longer sensed system pressure they fully opened allowing the full flow of high-pressure gas to be released into the distribution system supplying the neighborhood, exceeding the maximum allowable pressure.

Columbia Gas developed and approved the work package executed on the day of the accident. The work package did not account for the location of the sensing lines or require their relocation to ensure the regulators were sensing actual system pressure. The work was performed in accordance with steps laid out in the work package. In light of this accident, Columbia Gas implemented a safety stand-down for all employees who perform work related to low-pressure natural gas systems for NiSource subsidiaries.[4]
Minutes before the fires and explosions occurred, the Columbia Gas monitoring center in Columbus, Ohio, received two high-pressure alarms for the South Lawrence gas pressure system: one at 4:04 p.m. and the other at 4:05 p.m. The monitoring center had no control capability to close or open valves; its only capability was to monitor pressures on the distribution system and advise field technicians accordingly. Following company protocol, at 4:06 p.m., the Columbia Gas controller reported the high-pressure event to the Meters and Regulations group in Lawrence. A local resident made the first 9-1-1 call to Lawrence emergency services at 4:11 p.m.

Columbia Gas shut down the regulator at issue by about 4:30 p.m. The critical valves of the involved natural gas distribution system were closed by 7:24 p.m. Beginning about midnight, crews consisting of two Columbia Gas technicians escorted by two emergency response personnel began shutting off the meters at each house to isolate the homes from the natural gas distribution system. All meters were shut off by the following morning.
National Transportation Safety Board (NTSB) Chairman Robert Sumwalt and Member Jennifer Homendy led a 19-member NTSB team on scene. Parties to the investigation include NiSource, Columbia Gas, Pipeline and Hazardous Materials Safety Administration, Massachusetts State Police, and Massachusetts Department of Public Utilities. In addition to the on-scene work, investigators interviewed multiple people including two Columbia Gas Supervisory Control and Data Acquisition controllers from Columbus, Ohio.

According to Columbia Gas, all cast iron and bare steel piping in the affected neighborhoods will be replaced due to system integrity concerns. The new system will consist of high-pressure plastic mains with regulators at each service meter to reduce the line pressure from the main to the required pressure. The Massachusetts Department of Public Utilities is providing oversight of the new system installation to ensure that all work complies with state and federal safety regulations.

The NTSB’s investigation into this accident is ongoing. Future investigative issues include the coordination between the emergency responders and Columbia Gas; an analysis of the engineering work package preparation and execution, including the design documentation; and a review of construction packages for constructability and safety.


1. Title 49 Code of Federal Regulations (CFR) 192.3 defines a low-pressure distribution system as “a distribution system in which the gas pressure in the main is substantially the same as the pressure provided to the customer.” The Massachusetts Natural Gas Pipeline Safety Code, Title 220 Code of Massachusetts Regulations (CMR) 101.06, further defines a low-pressure distribution system “as any system in which the gas pressure in the main is equal to or less than two psig (pounds per square inch gauge).”
2. Columbia Gas delivers natural gas to about 320,000 natural gas customers in southeastern Massachusetts, including the Merrimack Valley.
3. Title 49 CFR 192.3 defines a high-pressure distribution system as “a distribution system in which the gas pressure in the main is higher than the pressure provided to the customer.” The Massachusetts Natural Gas Pipeline Safety Code, 220 CMR 101.06, further defines a high-pressure distribution system “as a system in which the pressure in the main is greater than 60 psig, but equal to or less than 200 psig.”
4. A safety stand-down is an organized break from work by which employers hold discussions with their employees. They are often taken as occasions to discuss safety topics while also reinforcing the organization’s policies regarding safety in general.

Probable Cause

 ​The information in this report is preliminary and will be either supplemented or corrected during the course of the investigation.
 

EPA Hits 13-Year High in Deleting Superfund Sites, Including Omaha Lead Site in Nebraska

EPA Hits 13-Year High in Deleting Superfund Sites, Including Omaha Lead Site in Nebraska

10/10/2018
Contact Information: 
EPA Press Office (press@epa.gov)
Environmental News
FOR IMMEDIATE RELEASE
EPA seal(Lenexa, Kan., Oct. 10, 2018) - 

Today, the U.S. Environmental Protection Agency (EPA) announced that in fiscal year (FY) 2018, the Agency deleted all or part of 22 sites from Superfund’s National Priorities List (NPL), the largest number of deletions in one year since FY 2005 and a significant increase over the past few years.

“Under President Trump, EPA is deleting Superfund sites from the National Priorities List at the fastest pace in more than a decade,” said EPA Acting Administrator Andrew Wheeler. “This remarkable accomplishment is proof that cleaning up contaminated lands and returning them to safe and productive use is a top priority of the Trump EPA.”
Under the Trump administration, the Superfund program has reemerged as a priority to fulfill and strengthen the Agency’s core mission of protecting human health and the environment. In May 2017, EPA launched the Superfund Task Force to provide recommendations for improving and expediting site cleanups and promoting redevelopment.

Site deletions have been a major focus of the Superfund Task Force. The Task Force reviewed existing policies and procedures related to deleting sites from the NPL and issued several recommendations. In addition, the Superfund program began providing the EPA administrator’s office with monthly updates on upcoming deletions. Through these and other actions, EPA deleted 18 sites and portions of four more sites in FY 2018, a significant increase over the three full or partial deletions in FY 2016.

Another significant Task Force achievement in FY 2018 was increasing the annual number of sites returned to communities for redevelopment. By redeveloping Superfund sites, communities are able to reuse thousands of acres of formerly contaminated land, often strengthening local economies. Many sites that EPA has designated as ready for reuse in previous years now host parks, business districts, renewable energy facilities, wildlife habitat, neighborhoods, and farms. In FY 2018, EPA committed to increase the number of NPL sites that achieved sitewide ready for anticipated use (SWRAU) by roughly 25 percent over the previous year. Through focused management attention and improved program practices, EPA achieved this goal: 51 sites reached SWRAU in FY 2018, the highest total since FY 2013.

The 18 sites EPA completely deleted from the NPL are:
  1. C & D Recycling in Foster Township, Pennsylvania
  2. Davenport and Flagstaff Smelters in Sandy, Utah
  3. Davis Timber Company in Hattiesburg, Mississippi
  4. Dorney Road Landfill in Upper Macungie Township, Pennsylvania
  5. Eureka Mills in Eureka, Utah
  6. Frontier Hard Chrome, Inc. in Vancouver, Washington
  7. Fulton Terminals in Fulton, New York
  8. Hatheway & Patterson in Mansfield, Massachusetts
  9. Nutting Truck & Caster Co. in Faribault, Minnesota
  10. Old Esco Manufacturing in Greenville, Texas
  11. Old Southington Landfill in Southington, Connecticut
  12. Ordnance Works Disposal Areas in Morgantown, West Virginia
  13. Reasor Chemical Company in Castle Hayne, North Carolina
  14. Recticon/Allied Steel Corp. in East Coventry Township, Pennsylvania
  15. Union Chemical Co., Inc. in South Hope, Maine
  16. Vancouver Water Station #1 Contamination in Vancouver, Washington
  17. Vancouver Water Station #4 Contamination in Vancouver, Washington
  18. Whitehouse Oil Pits in Whitehouse, Florida
The four sites EPA partially deleted are:
  1. Naval Industrial Reserve Ordnance Plant in Fridley, Minnesota
  2. Omaha Lead in Omaha, Nebraska
  3. Pacific Coast Pipe Lines in Fillmore, California
  4. Peters Cartridge Factory in Kings Mills, Ohio
Background

The NPL includes the nation’s most serious hazardous waste sites. The list serves as the basis for prioritizing EPA Superfund cleanup funding and enforcement actions. EPA deletes sites from the NPL when no further cleanup is required to protect human health or the environment.

One of EPA’s goals for the Superfund program is to return sites to communities for productive use. EPA encourages site reuse throughout the cleanup process, as appropriate, to maximize redevelopment opportunities. Superfund deletions can aid redevelopment efforts by offering a clear signal to developers and financial institutions that Superfund cleanup is complete.

In coming years, EPA will continue its focus on deleting sites through training and sharing information about the most effective approaches for moving sites to deletion.

EPA is scheduled to conclude implementing the Superfund Task Force recommendations in 2019.
  • Learn more about EPA’s Superfund Task Force
  • Additional information about EPA’s NPL deletions can be viewed online.
  • To search for information about these and other NPL sites, please visit EPA’s website.

USEPA Finalizes Plan to Remove Contamination Source and Expand Groundwater Treatment at the Combe Fill South Landfill Superfund Site in Chester Township, N.J.




EPA Finalizes Plan to Remove Contamination Source and Expand Groundwater Treatment at the Combe Fill South Landfill Superfund Site in Chester Township, N.J.
10/11/2018
Contact Information:
Elias Rodriguez (rodriguez.elias@epa.gov)
212-637-3664

(New York, N.Y.) Today, the U.S. Environmental Protection Agency (EPA) announced that it has finalized a plan to address a newly identified contaminant and enhance treatment of contamination at the Combe Fill South Landfill site located in Chester Township in N.J., an inactive municipal landfill covering 65 acres. EPA’s cleanup plan includes expanding and enhancing the existing groundwater treatment system that is currently operating at the site in addition to excavating and removing an area of materials that are a contributing source of contamination.

"This cleanup targets a deeper layer of groundwater contamination by expanding and enhancing on-site treatment capabilities,” said EPA Regional Administrator Pete Lopez. “The enhancements to groundwater cleanup at the Combe Fill South site will provide further protections to Chester residents and underscores EPA’s commitment to addressing toxic legacies such as non-compliant landfills and open dumps.”

The cleanup targets the landfill's impact on a deeper layer of groundwater that is contaminated with volatile organic compounds, including 1,4 dioxane. The current system extracts and treats mostly shallow groundwater directly under the landfill, along with a limited amount of deeper groundwater from the bedrock aquifer below the landfill. EPA will make improvements to this treatment system, including, the addition of deeper groundwater extraction wells to capture more contamination. In addition, EPA will make improvements to the plant to handle the additional groundwater and effectively treat 1,4-dioxane, a contaminant that has recently been detected at the site but not treated by the current groundwater treatment system. Additionally, EPA will remove waste materials from a portion of the landfill that is contributing to the contamination of the deep groundwater. EPA’s cleanup plan also includes long-term monitoring of deep groundwater contamination in areas outside the Combe Fill South Landfill Superfund site.

EPA held a public meeting in August 2018 to explain its cleanup proposal, discuss the other cleanup options that were considered, and to solicit public comments. To read the EPA’s selected cleanup plan, please visit: https://www.epa.gov/superfund/combe-fill-south

For a direct link to the Record of Decision, visit: https://semspub.epa.gov/src/document/02/550182

Background

The Combe Fill South Landfill, in Morris County, NJ, served as a municipal landfill from the 1940s until 1981. Soil and groundwater at the site were contaminated by volatile organic compounds from the landfill. Combe Fill Corporation went bankrupt in 1981 and the landfill was not properly closed. The original cleanup plan for the site included capping the landfill, installing a landfill gas collection system, pumping and treating the shallow groundwater beneath the site, and installing storm water runoff controls. By 1997, these actions were successfully completed. The system to treat shallow groundwater continues to operate at the site.

Starting in the early 1990s, the New Jersey Department of Environmental Protection began providing in-home water treatment systems to residents whose wells were potentially impacted by contamination coming from the landfill.

In 2015, EPA extended a water line to provide a permanent safe source of drinking water to 73 homes and businesses threatened by contaminated groundwater from the site. With the water line extension providing a permanent safe water supply to the neighborhood around the landfill, homes and local businesses no longer needed treatment systems.

The Superfund program has been providing important health benefits to communities across the country for more than 35 years. Superfund cleanups also strengthen local economies. Data collected through 2017 shows that at 487 Superfund sites in reuse, approximately 6,600 businesses are generating $43.6 billion in sales and employ 156,000 people who earned a combined income of $11.2 billion.

Under the Trump Administration, the Superfund program has reemerged as a priority to fulfill and strengthen EPA’s core mission of protecting human health and the environment.

On the one-year anniversary of the EPA’s Superfund Task Force Report, EPA announced significant progress in carrying out the report’s recommendations. These achievements will provide certainty to communities, state partners, and developers that the nation’s most hazardous sites will be cleaned up as quickly and safely as possible.

EPA’s “Superfund Task Force Recommendations 2018 Update” is available at: https://www.epa.gov/superfund/superfund-task-force-recommendations-2018-update.

Wednesday, October 10, 2018

Food safety recommendations for those who may be impacted by Hurricane Michael.



USDA Offers Food Safety Tips for Areas Affected by Hurricane Michael


USDA Office of Communications
Press (202) 720-9113
Consumer Inquiries (888) 674-6854
 
WASHINGTON, Oct. 10, 2018 — The U.S. Department of Agriculture’s (USDA) Food Safety and Inspection Service (FSIS) is issuing food safety recommendations for those who may be impacted by Hurricane Michael.

The National Hurricane Center expects storm surge and hurricane force winds in portions of Florida, Georgia and Alabama. Heavy rainfall from Hurricane Michael could produce flash flooding from the Florida Panhandle and Big Bend region into portions of Georgia, South Carolina, North Carolina and southeast Virginia.

Hurricanes present the possibility of power outages and flooding that can compromise the safety of stored food. Residents in the path of this storm should pay close attention to the forecast. FSIS recommends that consumers take the following steps to reduce food waste and the risk of foodborne illness during this and other severe weather events.

Steps to follow in advance of losing power:
  • Keep appliance thermometers in both the refrigerator and the freezer to ensure temperatures remain food safe during a power outage. Safe temperatures are 40°F or lower in the refrigerator, 0°F or lower in the freezer.
  • Freeze water in one-quart plastic storage bags or small containers prior to a storm. These containers are small enough to fit around the food in the refrigerator and freezer to help keep food cold. Remember, water expands when it freezes, so don’t overfill the containers.
  • Freeze refrigerated items, such as leftovers, milk and fresh meat and poultry that you may not need immediately—this helps keep them at a safe temperature longer.
  • Know where you can get dry ice or block ice.
  • Have coolers on hand to keep refrigerator food cold if the power will be out for more than four hours.
  • Group foods together in the freezer—this ‘igloo’ effect helps the food stay cold longer.
  • Keep a few days’ worth of ready-to-eat foods that do not require cooking or cooling. 
Steps to follow if the power goes out:
  • Keep the refrigerator and freezer doors closed as much as possible. A refrigerator will keep food cold for about four hours if the door is kept closed. A full freezer will hold its temperature for about 48 hours (24 hours if half-full).
  • Place meat and poultry to one side of the freezer or on a tray to prevent cross contamination of thawing juices.
  • Use dry or block ice to keep the refrigerator as cold as possible during an extended power outage. Fifty pounds of dry ice should keep a fully-stocked 18-cubic-feet freezer cold for two days. 
Food safety after a flood:
  • Do not eat any food that may have come into contact with flood water—this would include raw fruits and vegetables, cartons of milk or eggs.
  • Discard any food that is not in a waterproof container if there is any chance that it has come into contact with flood water. Food containers that are not waterproof include those packaged in plastic wrap or cardboard, or those with screw‐caps, snap lids, pull tops and crimped caps. Flood waters can enter into any of these containers and contaminate the food inside. Also, discard cardboard juice/milk/baby formula boxes and home-canned foods if they have come in contact with flood water, because they cannot be effectively cleaned and sanitized.
  • Inspect canned foods and discard any food in damaged cans. Can damage is shown by swelling, leakage, punctures, holes, fractures, extensive deep rusting or crushing/denting severe enough to prevent normal stacking or opening with a manual, wheel‐type can opener. 
Steps to follow after a weather emergency:
  • Check the temperature inside of your refrigerator and freezer. Discard any perishable food (such as meat, poultry, seafood, eggs or leftovers) that has been above 40°F for two hours or more.
  • Check each item separately. Throw out any food that has an unusual odor, color or texture or feels warm to the touch.
  • Check frozen food for ice crystals. The food in your freezer that partially or completely thawed may be safely refrozen if it still contains ice crystals or is 40°F or below.
  • Never taste a food to decide if it’s safe.
  • When in doubt, throw it out.
FSIS’ YouTube video “Food Safety During Power Outages” has instructions for keeping frozen and refrigerated food safe. The publication “A Consumer’s Guide to Food Safety: Severe Storms and Hurricanes” can be downloaded and printed for reference during a power outage. Infographics on FSIS’ Flickr page outline steps you can take before, during and after severe weather, power outages and flooding. FSIS provides relevant food safety information during disasters on Twitter @USDAFoodSafety and Facebook.

If you have questions about food safety during severe weather, or any other food safety topics, call the USDA Meat & Poultry Hotline at 1-888MPHotline or chat live with a food safety specialist at AskKaren.gov. These services are available in English and Spanish from 10 a.m. to 6 p.m. Eastern Time, Monday through Friday. Answers to frequently asked question can also be found 24/7 at AskKaren.gov.