CAUSE AND CONTRIBUTING FACTORS OF FAILURE OF GEARED WIND TURBINES, Part 1


CAUSE AND CONTRIBUTING FACTORS OF FAILURE OF GEARED WIND TURBINES, Part 1
Wind turbine on fire

The geared wind turbines continue to be plagued by numerous gearbox (more accurately the bearings within the gearbox), blade, mechanical, weather-related (e.g. lightning), design and maintenance issues. 

Just yesterday Siemens announced that the wind projects are not viable without heavy government subsidies. The failure of the bearings located within the gearbox is the most significant problem associated with the turbines This year, Siemens, a main manufacturer of wind turbines, reported a charge of 48 million Euros for inspecting and replacing defective main bearings in some onshore wind turbines. Structural and mechanical failures (which can result in a tower collapse) are primarily due to control system errors and lack of effective maintenance. 

If it was not for the government subsidizing of these systems, they would have never been built that way. This blog addresses the major causes of failure of wind turbines.

Wind turbines generate electricity through the wind-induced rotation of two to three aerodynamic blades located around a rotor. The rotor is connected to the main shaft that is connected to a generator that in turn spins to create electricity. We have seen wind turbines smaller than 100 kW and as large as 6,000 kW. The wind turbines can generate electricity to run a single piece of equipment (e.g. a water irrigation pump) at a particular facility or can produce electricity for sale to a power grid. 

The annual wind turbine capacity of the United States continues to grow exponentially. This growth is fueled by investment tax credits, federal goals of mandatory generation of electricity from renewable sources, rising energy demand, and other factors.

The biggest wind turbine manufacturers include General Electric, Vestas, Siemens, Clipper, Mitsubishi, Suzlon, Alstom, and Gamesa.

Crews lift a blade assembly onto the nacelle of Gamesa's G9X-2.0-megawatt turbine at the NWTC. 

The main components of a wind turbine system are:

· Tower, made from tubular steel, concrete, or steel lattice;
· Foundation for the turbine’s tower, nacelle and rotor blades;
· Nacelle; it houses the mechanical, electrical, electronic and other components of the turbine;
· Rotor Blades that rotate and cause the rotor to spin;
· Transformer;
· Generator that produces AC electricity from mechanical (rotational) energy; usually an induction generator;
· Rotor; it is formed by the blades and the hub;
· Brake that stops the rotor;
· Tail, but not all turbine types have tails;
· Gearbox that changes between the low and high gear shaft to increase the rotational speed to 1,000-1,800 rpm;
· Electronic control panel ;
· Shafts (low and high speed) connecting the rotor to the generator
· Blade power control system (controls the blade pitch and the yaw);
· Anemometer (wind speed control) and wind vane (wind direction control)

Anatomy of a wind turbine


A commercial, utility-scale wind energy generation facility typically consists of tens to hundreds of wind turbines capable of generating hundreds of megawatts of renewable energy. In addition to the wind turbines, other facilities associated with a wind farm project include access roads, temporary crane paths, underground power collection lines, aboveground generation tie lines (gen-tie), collector substations, interconnection switch yard, several permanent and temporary meteorological towers, and operations and maintenance building.

A 6,000-kW offshore wind turbine


The useful life of these wind turbines is supposed to be 20 years. However, the turbines have been plagued by numerous problems and this 20-year life is rather a utopia than anything else. Gearboxes and bearings in wind turbines, more than those in any other application, tend to fail prematurely. In fact, at some wind projects, up to half of all bearings inside the gearboxes fail within a few years. 

There are several reasons for this, including the poor understanding of gear functioning during storms and gusty winds, relative immaturity of the technology and industry, the rapid evolution of turbines to extra-large sizes, poor understanding of turbine loads, and an emerging (and largely unexplained) failure mode in turbine bearings called axial cracking.

Axial cracking in the gearbox of the wind turbine


The fact that the manufacturers of the turbines provide only a two-year warranty, is pretty good evidence of the reliability of this technology at this time. For example, the catastrophic gear box failures appear to be caused primarily by induced mechanical voltage straying through the gearbox, pitting the bearings. This has happened, in some cases, within 18 months after the turbine was placed into service.


Insurance for Wind Farms and Turbines

Like any piece of complex machinery operating under stress, turbines can fail. They break. They develop faults. They are improperly constructed. They are improperly maintained, and so on. And without the right care and protection policy in place, the resultant claim can quickly spiral out of control. For the owner and investor, this can lead to lost revenue and operational downtime; at worse, it means absorbing an increasingly daunting repair bill. We outline the top causes for turbine failure and explain what to do when things go wrong.


Wind farm insurance packages can include: construction insurance, physical damage, and third-party liability insurance coverage for delays in building of a wind farm, loss of earnings, and business interruption once the operation is running. Specifically, wind turbine coverage can compensate the policyholder for production losses if the wind farm’s annual wind levels fall below forecast.
Based on our investigations, we list below the most commonly encountered causes of wind turbine failures:

· Bearings and Gearbox issues – this is the Achilles Heel of the Gear-Driven Turbine
· Lightning strikes
· Blade design, manufacturing and installation issues
· Mechanical Breakdown (generators and transformers, burning the windings due to overspeed, etc.)
· Hydraulic failures
· Wind turbine and wind farm electric systems
· Grid failures
· Nacelle fire
· Improper handling during transportation, construction and improper assembly
· Human error(s) in O&M, construction and design
· Turbine collapse
· Natural Catastrophic events
· Yaw motor events
· Poor O&M arrangements
· Axial Stress
· Foundation damage
· Icing
· Accumulation of bugs, dirt and other debris
· For offshore turbines, the power converter suffers from high failure rates

We will address these failure modes below. 

Fires

In a typical year we expect to see total losses – typically caused by a fire – whereby the unit can no longer be repaired and is declared a total loss. In these instances, the most common causes are internal component failure or a buildup of material in lubricants. This can start an escalating spiral of sequential events and a rather spectacular – if not expensive – mechanical fire.

Fires are the second highest cause of catastrophic turbine failure

Extreme Weather

In occasional circumstances, extreme weather is also responsible for failure – whereby the wind speed and the elements simply become too much for the engineering dynamics of the machine. Brakes fail, blades seize up and the chain of events continues to make things worse.

Root Causes of Generator Failure

The main root causes of failure of generators at wind turbine sites include but are not limited to:

· Failure to follow recommend maintenance practices regarding the lubrication procedures, collector systems, etc.; mechanical or electrical failure of bearing, rotor lead failures, cooling system failures leading to excessive heat and fire.
· Lightning strikes, wind loading, weather extremes, lubricant contamination, thermal cycling, etc.
· Misalignment and other improper installation, excessive vibration, voltage irregularities, convertor failure, improper grounding, overspeed that results in burning of the windings, etc.
· Manufacturing and/or design failures, such as, loose components (wedges, banding), inadequate electrical insulation, transient shaft voltages, poorly designed/crimped lead connectors, rotor lead failures, the presence of other components inside the nacelle that complicate service, etc.
· For generators that are less than 1,000-kW, the most common failure mode is damage to rotor, following by stator, bearings, collector rings and miscellaneous generator failures. For generators that are between 1,000- and 2,000-kW, the most common failure mode was associated with the bearings, followed by collector rings, rotor, stator, cooling system, rotor leads and miscellaneous failure modes. For generators that were greater than 2,000-KW, the most common failure mode was associated with bearings, followed by stator, stator wedge, rotor, rotor leads, collector rings and miscellaneous failures. 

Maintenance is the critical factor affecting machinery life. Proper repairs are also critical to the reliability and longevity of the turbine generator.

Damage to the generator windings due to over-speed and subsequent overheating of the windings

Then there are the gearbox and blade lightning strikes.
Again, these create a spectacular display but also a spectacularly large loss – with the resultant damage often requiring either extensive turbine down time and a complex replacement or repair.

Blade Failure Modes

The main causes of failure of turbine blades include: lightning strikes, foreign object damage, poor design, material failure, power regulator failure. A combined thermal and stress analysis of a lightning strike model of typical wind turbine blade material (including E-glass composite layups) shows that the fiberglass material immediately surrounding the lightning attachment location becomes damaged due to plastic deformation. Depending on the magnitude and number of lightning strikes, the blade has the potential to fail under an extreme static gust load, under fatigue, or a combination of the two.

Turbine blade damaged by lightning strike.


Accumulations of bugs, oil, and ice on the blades will also reduce power as much as 40%. Regular cleaning of the blades has become a maintenance requirement. Included in the hours of down time for cleaning the blades is ice built-up when the ice causes the airfoil shape to be changed and the turbine cannot produce power.

Broken wind blade


Bearing Failures - The Achilles Heel of Geared Wind Turbines

No matter what type of turbine model, mainshaft bearings are common failure points. The main reason: spherical roller bearings are not the optimal bearing configuration. Large amount of radial internal clearance (RIC) are needed to facilitate original bearing assembly at the manufacturer. Although this simplifies the assembly at the turbine OEM, this clearance is not well suited for handling axial loads. The proper bearing configuration would be a pre-loaded tapered roller bearing, but this would have increased both turbine assembly time, as well as purchased cost. 

As a result of this configuration, the thrust from the wind causes the mainshaft to move axially towards the gearbox until the clearance has been absorbed, hence unseating the upwind row while the downwind row now sees the majority of the load.

The primary failure mode of the mainshaft bearing is macropitting (spalling) of the downwind race. The unloaded upwind row will then skid and skew as result of having no roller tractions, creating a second failure mode of micropitting. The micropitting is also called ‘grey staining’ or ‘frosting’. 

This consists of microscopic cracks only a few microns deep (about .0001 inches). Individually these cracks are too small to be visible. As they accumulate they appear as grey stains on the roller surface. Eventually the bearing roller starts to shed its cracked and weakened surface losing a small bit of its precision tolerance. Furthermore, this contaminates the oil with microscopic super hard steel particles most of which are too small to be filtered out. Why does grey staining begin? Typically it is a breakdown of the oil film that separates the rollers from the races.


There are many opinions in the public domain summarizing common indications of specific operating conditions in conjunction with premature failures in wind turbine applications: 

· periods of heavy and dynamic loads/torques – leading to vibrations and rapid load changes (e.g. transient raceway stress exceeding 3.1 GPa, heavy loads of 15,000 per year, impact loads). Such transient events can include: grid loss, high wind shutdowns, wind gusts, curtailments, control malfunctions, generator short circuits, resonant vibration, misc emergency stops. Although these reversals are infrequent, they can be severe.
· depending on turbine type, additional radial and axial forces by the rotor, axial motion of the main shaft – leading to dynamical loading, higher stresses of gearbox components especially in the first stage
· occasional connecting and disconnecting of the generator to/from the power grid – leading to torque reversals and bouncing effects (which e.g. can lead up to 2.5-4 times higher nominal torque and impact loads)
· rapid accelerations/decelerations and motions of the gearbox shafts
· misalignment, structural deformations (nacelle hub, housings)
· lubricant compromise between needs of gears and bearings as well as between low and high speed stages, insufficient oil drains and refill intervals
· harsh environmental conditions – possible large temperature changes and consequently larger temperature differences between the bearing inner ring and housing than expected when starting up, dust, cold climate, moisture and salt water (especially for off-and near-shore turbines)
· idling conditions – leading to low load conditions and risk of skidding damage (adhesive wear) and wear in the low running stage
· conflicting design needs, e.g. increasing rolling element size will increase the load capacity but simultaneously increase the risk for cage-and roller slip and sliding damage

As stated above, bearings may fail due to other reasons not covered by best practice standards and from other industrial experiences. 

Statistical evaluations of onshore and offshore wind turbines indicate clearly a correlation between failure rate, wind speed and heavy and fluctuating loads.

Metropolitan Engineering, Consulting & Forensics (MECF)
Providing Competent, Expert and Objective Investigative Engineering and Consulting Services
P.O. Box 520
Tenafly, NJ 07670-0520
Tel.: (973) 897-8162
Fax: (973) 810-0440
E-mail: metroforensics@gmail.com
We are happy to announce the launch of our twitter account. Please make sure to follow us at @MetropForensics or @metroforensics1
Metropolitan appreciates your business.
Feel free to recommend our services to your friends and colleagues.

HOW TO PREVENT AN OVERHEATED BOILER OR FURNACE INCIDENT


HOW TO PREVENT AN OVERHEATED BOILER OR FURNACE INCIDENT

https://sites.google.com/site/metroforensics3/cause-and-contributing-factors-of-heating-boiler-failure





Explosion of an overheated boiler

We received quite a few inquiries regarding the prevention of the overheating of a boiler or furnace that could lead to an explosion. If you have baseboard heating system in your home, then you do have a water heating boiler system like the one we describe in this blog. We briefly address this issue as a service to the communities we serve.

An overheated boiler is where the heating unit reaches an exceedingly high temperature and pressure, and the high temperature and pressure safety switches will not operate. This condition, also known as “runaway boiler”, is very hazardous to building occupants and emergency responders, including the neighbors. It is caused by the concurrent failures of redundant safety controls that maintain safe temperature, pressure, gas supply (if the boiler is a gas unit), and water supply. 

When boilers or furnaces overheat, it can cause a failure of the safety controls that are attached or very close to the body of the boiler. The failure of the safety controls will most definitely cause an explosion of the boiler. See images above and below.




Exploded boiler on its side


There are several types of boilers and furnaces available: hot water boilers, steam boilers, warm air furnaces. These are briefly described below.


Basic Components of a Hot Water Boiler


The basic components of a hot water boiler are (refer to the attached schematic):


· A gas valve where the fuel comes in


· Water feed gate valve and the associated pressure relief valve (PRV)


· The water circulator pump


· The pressure relief valve


· The air vent


· The Aquastat control that is used to regulate the water temperature


· The expansion tank


· The drain valve


· The vent flue


· The burners


· The pressure and temperature gauges/control valves





The water heating boiler operates as follows:


The boiler is filled up with water and maintains 12 PSI (pounds per square inch) water pressure. The air is bled out of the system zones. The circulator pump will not move water through the baseboard loops if air is in the system. The expansion tank maintains system pressure and absorbs water expansion and contraction from heating and cooling.





How water boilers risk over-pressurization when there is a failure of the pressure relief valve and at least one other safety control. The boilers are connected to closed piping systems with the potential to build up excessive pressures when water temperatures rise without control beyond the safe operating range which is up to 250 degrees F. The typical maximum operating pressure of a residential boiler is 20 PSI. For an industrial boiler, the max operating pressure is 50 PSI. Pressures that continue to rise above the above safety ratings can result in a violent explosion when the boiler vessel fails.


Based on our forensic investigations, the boiler failure incidents occurred when safety controls failed to operate as designed due to mechanical failure (i.e., aquastat shorting out, damaged wiring, or failed gas valve). Other causes of failure include human intervention events, including: removing or adding a pressure relief valve to stop water leaks; wiring errors; opening a gas valve in bypass (manual) mode.


A “Dry Fire Boiler” condition can occur when burners fail to shut off and the relief valve opens to release excessive pressure. The remaining water in the system can boil away if water supply to the PRV is shut off or the PRV is stuck closed. Without water, the boiler can reach extreme temperatures. See image below of an overheated firebox of a boiler that was heating without water.






You should never introduce water in an overheated boiler. If cooler water is introduced, it flashes into steam when it comes into contact with the heated surfaces inside the boiler. This “flash steam” significantly increases the pressure in the boiler as the steam energy is released. This reaction can result in a cracked boiler or violent explosion.


Owners of Flooded Homes Beware: It is very important to note that the heating controls exposed to flood water can fail after being dried and placed back in operation. Any controls exposed to flood water must always be replaced.

_____________________________________________________________


Did you know?


NEVER ADD WATER TO AN OVERHEATED BOILER. WATER COULD FLASH INTO STEAM AND CAUSE SEVERE INJURY OR DEATH


_____________________________________________________________

Steam Boiler


The basic components of a steam boiler are as follows:


· The combination gas valve, regulator and shut-off cock


· The low water cutoff switch


· The water level sight glass


· The pressure limit control


· The temperature and pressure relief valve


· The exhaust vent damper


· The electronic ignition


· The access door to the burners/pilot






Steam boilers can become over-pressurized when there is a failure of the pressure relief valve and at least one other control. Although the steam boiler is connected to an open piping system with radiators at the endpoints, the radiator air vents close at normal operating temperatures. Excessive pressure will build up if the gas valve or safety controls fail. Boiler pressures that exceed 15 PSI due to a failure of the PRV can result in a violent explosion when the boiler vessel fails.


Investigated boiler failure incidents took place when safety controls failed to operate as designed due to mechanical failure (i.e., blocked siphon tube (“pigtail”), failed gas valve, defective low level cutoff (LWCO) or though human intervention. Some examples of human intervention are: removing and adding a PRV to stop water leaks, wiring errors, opening a gas valve in bypass (manual mode).

As we said earlier, the leading cause of boiler failure is the low water condition caused by failure of the LWCO device. The following factors can lead to a breakdown or malfunctioning of the LWCO.







Float Type LWCO w/ Manual Reset (Steam or Water Boiler)

· Mineral deposits (calcium, etc.) typically contained in the water cause fouling of the device.


· Improper or faulty wiring, either permanent or during testing are causing malfunctioning of the LWCO.


· Normal wear and tear of the device can lead to failure.


· Luck or proper maintenance such as purging.


· Loss of Water due to leaks in piping, steam traps, etc.





LWCO switch stuck in the up position. This led to a boiler overheating, introduction of water into the overheated boiler, steam flashing and subsequent explosion


Warm Air Furnace


If you have a typical HVAC system, then you have a warm air furnace as part of the system. The basic components of a warm air furnace include:


· The gas valve


· The gas burners


· The blower and blower motor


· The furnace chamber


· The blower fan and limit control


· The gas shut off valve


· The heat exchanger


· The pilot assembly of hot surface ignitor


· The thermocouple or flame sensor

A warm air furnace is at risk of overheating when gas control failures produce temperatures exceeding the maximum design. An overheated furnace is a fire hazard and may crack, allowing carbon monoxide to enter the building through the duct work. For HVAC installations, if an A/C coil fails due to soft solder melting when high temperatures or fire compromises the system, potentially lethal toxic gas can be created. As with the other boilers, any controls exposed to flood water must always be replaced.


In a boiler explosion incident, the homeowner was experiencing trouble with the boiler ignition system, and switched the automatic gas valve to manual operation. The constant flow of gas into the boiler led to a significant increase in temperature and pressure that caused an overheating (runaway) condition. Fifteen minutes after the heating unit was turned on, the boiler exploded.





Pieces of the boiler scattered in the basement






Automatic gas valve was switched “ON” to manual operation, feeding the boiler with a steady flow of gas. This led to the overheating and subsequent explosion of the boiler. This particular boiler had no means to relieve pressure after overheating.

Several months prior to the explosion, the customer had a combination pressure reducing (water feed) valve and pressure relief valve control replaced. When the servicing company performed the repair, the combination valve was replaced with only a pressure reducing (water feed) valve. As a result, the boiler no longer had a relief valve to relieve excess pressure. Whenever a combination valve is replaced with a single pressure reducing (water feed) valve, a separate relief valve must also be installed. Boilers are equipped with designated tap holes for inserting a separate pressure relief valve.

In another incident, a homeowner had a thermal expansion tank installed on the supply line to the hot water boiler. The new expansion tank was erroneously connected to the outlet of the pressure relief valve, plugging it. The boiler had no way of relieving pressure and created a “runaway” condition.





Note the expansion tank erroneously connected to the outlet of the PRV valve. This was the cause of boiler explosion.

Based on the thousands of boiler maintenance, repairs and failure investigations we conducted over the years, we can tell you with certainty that the leading cause of heating boiler failure is low water. Most of the time, the low water fuel cutout safety switch has failed and this led to the overheating and failure of the boilers. There are always early sign of boiler failure, if you know where to look and how to interpret them. For example, small leaks could appear in the boiler vessel or the piping. These water leaks may not look serious, but they should never be ignored as they will most certainly lead into greater problems. Most of the time, some low cost items, such as a pressure relief valve, are defective or are old and need replacement. If they are not replaced, significant losses could occur.

If an insurer has refused to insurer your boiler, then this should be a good clue that it is time to replace it or repair it. Insurers, like The Hartford Steam Boiler Inspection and Insurance Company, Travelers, and others have a very good handle on boiler safety. When they stay away from a piece of equipment, please take the hint.





Above is a photo of a valve that was installed incorrectly. In fact, the inlet and outlet were stamped on the valve, so there is no excuse for such error. Mistakes are more frequent than you think. It is that our inspections help caught them prior to any damage occurring.



Why Boiler Failures can be Dangerous


Water boils at atmospheric pressure at 100o C (212o F). When placed under pressure, the water can be heated to extremes without flashing to steam. The typical expansion rate for 1 cubic foot of water is 1,700 cubic feet of steam. This amazing expansion rate is the reason that the boiler explosions are so powerful. Imagine this amount of steam to exit from a small pipe break under tremendous pressures. The routinely inspected water heater holds 119 gallons (16 cubic feet) of water. It is really a small bomb due to this massive energy release; in the past (during the industrial revolution between the 1800s and early 1900s) thousands of people died from such explosions. See below the results from a failed relief valve.





Boiler Inspection and Maintenance


The following provide important recommendations for heating boiler inspection, maintenance, and operation prior to the heating season. Low pressure boilers are inspected annually while in operation and internally every 3 years, if construction permits:


1. Perform an external exam for leaks. Many times we find that the leakage is caused by failure to remove hardness from inside the boiler; then the hardness expands during boiler heating, pushing apart the boiler sections and causing leakage.


2. Perform an evaluation of all safety device function.


3. Test all high temperature and high pressure switches.


4. Insulate water lines that are exposed to freezing temperatures to avoid pipe freeze-ups. Quite a few of these freeze ups occurred this past winter and another round of equally severe winter is forecast. We have our fingers crossed.


5. The safety relief valves or devices are crucial devices that must be tested very frequently, ideally every month. A malfunctioning safety valve will cause the boiler fail. If the relief valve does not properly function, then the temperature control will fail to properly control temperature. The water heater will heat unchecked until catastrophic failure occurs.


6. All other valves, gauges, pressure and temperature control instruments must be inspected for proper functioning.


7. Due to constituents found in the water, we get sediment built up pretty much everywhere in the boiler, including the sight (or gage) glass used to observe the water level. The water level sight glass should be cleaned from the accumulated water impurities and scale.


8. Disassemble the low water fuel cutoff and make-up water feeding devices. All parts should be thoroughly flushed, cleaned and reconditioned as required, then tested and evaluated before the boiler is put into regular service. While in service the devices should be tested once a week for steam boilers and once a month for hot water boilers.


9. All leaking pipes, valves, connections, etc. must be repaired or replaced to prevent water loss and property damage.


10. The boiler burner should be cleaned and adjusted to provide maximum burning efficiency.


11. All the internal surfaces of the boiler should be cleaned of all the water impurities that accumulate over time. These impurities inside the boiler are the cause of corrosion, cracking, deterioration and even explosion of the boiler.


12. A chemical water treatment should be used to minimize built-up of scale and other deposits and to slow down or minimize corrosion.


13. Ensure that all other equipment associated with the boiling system work properly.


14. Maintain a record book of boiler operation, maintenance or repairs. Some boilers have failed because technicians did not know what another tech had done to the boiler.

Regarding pressure vessels, most mechanical codes require that are inspected once every three years. This inspection requires a test of:


· Safety relief devices


· Temperature and pressure controls


· External exam to check for leaks


· Testing to verify thickness of the vessel body


We commonly see leaking and corroded boilers during many of our inspections, especially for older boilers. Unfortunately, even with a regular inspection program, people just ignore proper maintenance and operation. Just like our cars, some people are good at maintaining and some people are simply bad. We also observe leaking steam from the spindle, and many steam and water connections are also found leaking. The mud drums are another area where we observe corrosion and leakage. See figure below.








We have seen situations where there is very little monitoring of boilers in schools and municipalities on a regular basis, other than the inspector doing his annual inspection. This has led to leaks and other problems with the boiler efficiency and operation. As we wrote in the beginning, the most frequently found deficiencies are associated with the low water fuel cut offs, safety and relief valves are stuck, and high pressure and temperature switches are not often installed.


 It appears that the boiler owners believe that the service technician who may maintain their boiler will also test for the operation of the safety devices. We have found that this is not true, as the technician will only perform the service of the combustion and burner fuel systems, change the fuel filters, clean the fuel pumps and nozzles, check the igniter, vacuum the gas passes of the boiler, perform an efficiency test of the unit, etc.


Metropolitan Engineering, Consulting & Forensics (MECF)



Providing Competent, Expert and Objective Investigative Engineering and Consulting Services

P.O. Box 520
Tenafly, NJ 07670-0520
Tel.: (973) 897-8162
Fax: (973) 810-0440
E-mail: metroforensics@gmail.com
Web pages: https://sites.google.com/site/metropolitanforensics/
https://sites.google.com/site/metropolitanenvironmental/
https://sites.google.com/site/metroforensics3/
We are happy to announce the launch of our twitter account. Please make sure to follow us at @MetropForensics or @metroforensics

Metropolitan appreciates your business.
Feel free to recommend our services to your friends and colleagues.