OIL & GAS WELL DRILLING RISKS - WELL SITE IGNITION SOURCES
There are a number of
potential sources of ignition for flammable gases and liquids on the drill
site. It is necessary to provide for a general ignition safety program which
could pre-empt potential hazards of fire and explosion.
Potential Hazard:
Ignition and explosions of
flammable gases or vapors from:
Internal-combustion engine
sparks
Open flames from any source
Smoking
Welding operations
Electric power tools
Two-way radios
Vehicles with catalytic
converters
Portable generators
Possible Solutions:
Provide spark arrestors for
internal-combustion engines.
Post "NO SMOKING"
signs wherever a flammable gas or vapor hazard exists.
Locate "spark
producing" equipment or facilities well away from potential hazard areas.
Prohibit vehicles with
catalytic converters from the immediate vicinity of the rig.
Prohibit open flames from the
vicinity of the rig.
Additional Information:
American Petroleum Institute
(API).
RP 54, Recommended Practice for Occupational Safety for Oil
and Gas Well Drilling and Servicing Operations, Wireline Service.
RP 500, 3rd Edition, Classification of Locations for
Electrical Installations at Petroleum
Facilities Classified as Class 1, Division 1 and Division 2.
Facilities Classified as Class 1, Division 1 and Division 2.
RP 505, 2nd Edition, Classification of Locations for
Electrical Installations at Petroleum
Facilities Classified as Class 1, Zone 0, Zone 1 and Zone 2.
Facilities Classified as Class 1, Zone 0, Zone 1 and Zone 2.
Accident Prevention Reference
Guide. International Association of Drilling Contractors (IADC).
29 CFR 1910.106, Flammable and Combustible Liquids.
OSHA Standard.
29 CFR 1910 Subpart S, Electrical. OSHA
Standards.