FIRE CAUSE & ORIGIN INVESTIGATIONS: LACK OF SCIENCE IS BEHIND MANY ARSON C&O INVESTIGATIONS



LACK OF SCIENCE IS BEHIND MANY ARSON CAUSE AND ORIGIN INVESTIGATIONS



Arson investigation, unfortunately, is a field where junk science has been the rule rather than the exception.  A large body of cause-and-effect mythology has developed in fire investigations over the years.  As far back as 30 years ago we have been arguing that the opinions stated by many fire investigators were not based on science and they were in fact false.  Due to these faulty opinions, many people were convicted of arson and many people lost their home and their livelihood.  Some people have allegedly been put to death having been convicted of arson, based on the same old cause-and-effect mythology.  

Through the 1980s, proponents (including ourselves) of a science-based approach to arson investigations waged an uphill battle, finally winning a major victory in 1992 when the National Fire Protection Association (NFPA) published its Guide for Fire and Explosion Investigations (NFPA 921).  NFPA 921 would subsequently become the bible in fire and arson investigations.
Prior to NFPA 921, the fundamental principles for determining the causes of fires did not involve science per se, but rather experience-based hypotheses that were not tested to determine their validity.  This process, known as “negative corpus,” relied on a process of elimination rather than supporting evidence or scientifically supported conclusions, and some investigators feared that a science-based approach would establish criteria of proof that would be too difficult to meet.  So, they fought NFPA 921.
The Daubert v. Merrell Dow Pharmaceuticals decision was handed down in 1993, where the U.S. Supreme Court made judges the gatekeepers of expert testimony.  The ruling said that judges have to determine if expert testimony is reliable, and that using a methodology that has been peer reviewed, published, and accepted was part of that reliability test.  So in cases that included fire investigations, courts began gravitating towards NFPA 921, a consensus document from a group of leaders in the fire investigation community.  The U.S. courts began referring to NFPA 921 as the “standard of care” for evaluating expert testimony regarding fire investigations.
An organization called the Innocence Project [which works to exonerate the wrongfully convicted] has taken an interest in arson cases.  They are going back and evaluating the science or lack thereof in investigations and comparing it with what’s available today.  They estimate that between 200 and 400 individuals may have been wrongly convicted of arson based on false evidence and false expert testimony using non-scientific methods.
We are also very gratified to see state legislatures now trying to reverse some of the wrongs committed over the years as a result of these false opinions and wrongful convictions.  In this blog lack of validity of common myths is reviewed, and new forensic engineering analysis techniques discussed consistent with the NFPA 921.
The COMM. ON IDENTIFYING THE NEEDS OF THE FORENSIC SCI. CMTY. ET AL., published the report entitled NAT’L RESEARCH COUNCIL OF THE NAT’L ACADS.,STRENGTHENING FORENSIC SCIENCE IN THE UNITED STATES: A PATH FORWARD (2009).  Therein, the report stated the following regarding the fire investigations:

By contrast, much more research is needed on the natural variability of burn patterns and damage characteristics and how they are affected by the presence of various accelerants. Despite the paucity of research, some arson investigators continue to make determinations about whether or not a particular fire was set.  However, according to testimony presented to the committee,[1] many of the rules of thumb that are typically assumed to indicate that an accelerant was used (e.g., “alligatoring” of wood, specific char patterns) have been shown not to be true.[2] Experiments should be designed to put arson investigations on a more solid scientific footing.
In the early 1990’s, fire investigators relied heavily upon the teachings of their mentors regarding the nuances involved in interpreting incendiary indicators.  Access to controlled burn experiments and other practical guidance regarding the science of fire behavior was limited.  At the national level, the NAS Report notes the prevalence of apprenticeship training across forensic disciplines, finding that reliance on “apprentice-type training” and a “guild-like structure” works against predictability. (NAS Report at 15-16.) Similarly, the knowledge levels on which fire investigation practices were based at the time were “extremely variable” due to the “one-on-one training that dominated.”  While scientific papers and textbooks describing some of the “modern” fire science principles existed in the early 1990’s, it is difficult to determine how widely those materials were disseminated, or whether they were understood and accepted by fire investigators at the time.
Perceived Gap in Understanding Between Fire Scientists and Fire Investigators
Many are concerned about perceived differences in understanding of fire indicators between the scientists and engineers who study principles underlying fire indicators, and the state and local professionals who respond to and investigate fires.  One challenge is the lack of science education on the part of many fire investigators.  Though this dynamic is changing as younger classes of investigators gain exposure to college coursework in chemistry and physics, most active investigators do not have scientific backgrounds.
Elimination of Accidental Causes
A critical component of successful fire investigation is the elimination of accidental causes.  The elimination of any single cause requires an investigator to use his or her judgment, and to request outside assistance when necessary.  For example, when considering whether a child could have set the fire in a case, investigators may conclude that the possibility was remote considering the ages of the children, the fact that no lighters were found near them and that a child’s gate blocked the bedroom doorway.  This is the sort of judgment that fire investigators typically must engage in during the course of an investigation.  Investigators would be required to make a similar judgment call today if the same facts were presented.
However, other components of assessing accidental causes have been assisted by developments in science and engineering over the last two decades.  For example, scientists and engineers have created methods that allow investigators to conduct a more thorough review of possible electrical malfunction as a point of origin.  In the early 1990’s, investigators routinely checked for shorts in the line after “pulling” the electrical meter for the safety of those on the scene, in accordance with the safety requirements of NFPA 921. (See NFPA 921, 1995 edition at 10-2.4.)  If there were no shorts in the line and no evidence of appliance malfunction, investigators concluded that the cause was not attributable to electrical malfunction.

Today’s investigators have additional tools at their disposal. For example, investigators can use the process of arc mapping (See 2011 edition of NFPA 921) to determine a fire’s possible point of origin.  Many local investigators are aware of the arc mapping process and often consult electrical engineers for assistance.
Pattern Indicators
As previously stated, the value of various incendiary indicators and the manner in which they are identified has changed since the early 1990’s.  Experts have identified indicators that were present in the Texas arson cases of Willingham (who was executed in 2004) and Willis (who was freed in 2004) that have since undergone extensive scientific testing and experimentation.  Such testing has provided scientists with a better understanding of the limitations of the indicators.  Many of these indicators may be present in arson cases where accelerants are used, thus requiring an investigator to use the scientific method as expressed in NFPA 921 to conduct a systematic review.  The discussion below does not examine every indicator used in the fire investigators’ reports but rather includes illustrative examples applicable to all arson cases.  Excerpts from fire scene reports and trial testimony, though inherently incomplete, provide a sense of the investigators’ understanding of incendiary indicators at the time of trial.  The question of when, why and how certain limitations should be applied to incendiary indicators is the subject of ongoing study by the fire science community.

The classic V thermal damage pattern is used by analysts to determine the origin of the fire, the base of the V being the likely origin of the fire

1.    V-Pattern as Indicator of Origin

                                               Family room V-Pattern

A Fire Marshal’s report discusses “V-patterns” as an indicator of fire origin.  The report states:
The burn pattern on the east and west wall of the hallway disclosed a gradual climb in a 45 degree angle toward the south end and clearly showed a “V” pattern.  This “V” pattern is an indicator that the fire originated on the floor near the north end.  The north end area of the floor disclosed that the fire had burned through the tile blocks and caused charring of the wooden floor underneath.  The burn pattern on the floor and “V” burn patterns on the walls is an indication that a fire originated at the north end area of the center hallway.
The Fire Marshal also testified regarding “V” patterns as follows:
The photograph that sees the V pattern debris, that’s Exhibit No. 23. The one that tells where the V is, that’s possible origin of the fire.

In the early 1990’s, many fire investigators based their conclusions of origin in part on the theory that a “V-pattern” on a wall points to the origin of the fire.  For example, the 1995 edition of NFPA 921 4-17.1 stated: “the angled lines of demarcation, which produce the “V” pattern, can often be traced back, from the higher to lower levels, toward a point of origin.  The low point or vertex of the “V” may often indicate the point of origin.” NFPA 4-17.1 (1995 edition).
Scientists now know that the “V-pattern” simply points to where something was burning at some stage of the fire, not necessarily the origin.

V pattern suggests a fire origin at the red arrow in the vicinity of a stove top. There is some drop down burning debris as shown by the green arrow.

2.    Pour Patterns
A Fire Marshal testified as follows regarding his interpretation of pour patterns in the home he investigated:
So this area right here are what I call burn trailers. Burn trailers is like a trailer, you know, like a little path, a burnt path.  A pour pattern, which is a pattern like somebody put some liquid on the floor or wherever and, of course, when you pour liquid, then it creates a puddle.  Liquid creates puddles. When it rains you get puddles.  When the baby drops its milk, you create puddles.  If you ever drop a coke, you create puddles.  All this area has that, has the burn trailer pour patterns and configurations. This area right here, which is right here almost in front of this bed is deep charred.  The floor, it didn’t burn through the floor, but it burned the three layers of the floor.  And a pour pattern and trailer is an indication that somebody poured something, you know, either going in or out.

All fire goes up. All water goes down. Or any liquid goes down unless man changes the course.
Another Fire Investigator also testified regarding his interpretation of pour patterns in another case:
It appears to be burned areas resembling how a liquid would have run and burned on that surface. (Answer in response to a question regarding irregular floor patterns.)

“I have never run across that, no, sir.” (In response to the following question: “Now, in your experience, training, and your reading publications to keep up-to-date, have you or have you not heard of the phenomenon that radiation can cause irregular patterns?”)

“That’s correct.” (In response to counsel’s assertion that “fire burns up, not down.

In the early 1990’s, many fire investigators reasoned that fire moves upward (at least flames and hot gases do) and that carpet and flooring is difficult to ignite.  If one pours ignitable liquid on a floor, the carpet burns away in an irregular path similar to the deposits of the liquid.  Thus, it was often thought that pour patterns at floor level were “nearly proof alone” that the fire was started with an accelerant.  While such a fire could have been started with an accelerant (see e.g., NFPA 921 1995 edition, 4-17.7.2) other phenomena of fire behavior can also cause similar pour-like patterns.
For example, when a fire approaches or surpasses flashover conditions, all of the exposed carpet in the room will ignite.  Synthetic carpets and pads melt or decompose to liquid as they burn, producing highly irregular and unpredictable patterns.  The effect of ventilation conditions, radiant heat, flaming and smoldering debris, and drop-down burning from things like synthetic mattresses and bedding also affect the irregular burn patterns.
The term pour pattern implies that a liquid has been poured or otherwise distributed, and
therefore, is demonstrative of an intentional act. Because fire patterns resulting from burning ignitable liquids are not visually unique, the use of the term pour pattern and reference to the nature of the pattern should be avoided. The correct term for this fire pattern is an irregularly shaped fire pattern.
The presence of an ignitable liquid should be confirmed by laboratory analysis. The determination of the nature of an irregular pattern should not be made by visual interpretation of the pattern alone. See Figures below for examples of fire patterns on floors.


Fire Patterns on Floor Resulting from Fully Developed (Post-Flashover) Fire in Full Scale Test Burn of Residential Structure. Floor Was Carpeted and Room Had Typical Residential Furnishings; No Ignitible Liquids Were Present.



Fire Patterns on Linoleum Floor Resulting from Fully Developed (Post-Flashover) Fire in Full-Scale Test Burn of Residential Structure; No Ignitible Liquids Were Present.

•    Holes in the floor may be caused by glowing combustion, radiation or an ignitable liquid.
•    There is no justification that the appearance of large, curved blisters is an exclusive indicator of an accelerated fire.
•    The presence or absence of spalling should not, in and of itself, be construed as an indicator of the presence or absence of a liquid fuel accelerant.
•    Inverted cone patterns have been interpreted as proof of flammable liquid fires, but any fuel source that produced flame zones that do not become vertically restricted can produce inverted cone patterns.


Today, fire scientists and investigators should have a better understanding of the nuances of flashover conditions, including how to analyze their effects.  Rigorous, ongoing training is the key to ensuring that all investigators are knowledgeable about developments in the scientific community’s understanding of the complex chemical and physical phenomena involved in fires, including but not limited to the effects of flashover.

3.    Low/Deep Burning and Multiple Separate Points of Origin
A Fire Marshal testified as follows regarding his interpretation of low/deep burning and multiple separate points of origin:

And you got char burning, like for example, this is the bottom here.  It’s burned down here at the bottom.  That is an indicator in my investigation of an origin of fire because it’s the lowest part of the fire.

Multiple areas of origin indicate—especially if there is no connecting path, that they were intentionally set by human hands.

The first incendiary indicator is the auto ventilation. The inconsistency of the fire going out of this window and the fire going out of the door and this window here.  That’s inconsistent with fire behavior. That’s an indicator that it’s a possible incendiary fire.  Okay.  Puddle configurations, pour patterns, low char burning, charred floor, the underneath burning of the baseboard, the brown stains on the concrete, the underneath of the bed, because of the fire right underneath the bed, puddle configurations in that area, and the total saturation of this floor is indicated with pour patterns, because that’s all I’m doing is looking at the facts, at the evidence.

A Fire Investigator noted low burn as a significant indicator in another case as follows:

Initially, when we had finished the view of the exterior of the building and walked into the inside of the structure, there were a couple of things that caught our attention right off. First of all, the low burning on the walls almost to floor level.

The most highly significant would be the low burning to the floor level on some of the walls, and the burn patterns that I observed on the floor itself.

In my opinion, there was some type of flammable liquid applied there.  There was no other fuel source there that would have indicated it would have burned in that manner.

Low burn patterns may be an indicator of accelerant, but scientific experiments have also shown that radiant heat transfer causes low burn patterns, and that the radiant heat of a fully involved room fire can be sustained to penetrate floors deeply.  Scientific testing has also shown that ignitable liquids alone do not burn long enough to penetrate floors deeply.  Similarly, the appearance of multiple separate points of origin may provide evidence that a fire was intentionally set, but is often attributable to radiation and drop down effects.






Burn Patterns on a Floor of a Room Burned in a Test Fire in Which No Ignitable Liquids Were Used

 Configuration is also of critical importance when determining area of origin.  For example, fall down of something like curtains could cause an area of low burning.  That’s not an area of origin, but it can easily be mistaken for one or be taken as ‘evidence’ of multiple fires.  Another fire effect that can cause low burning is radiant line of sight, which is responsible for 1/3 of the heat of a fire

Typically, the difficulty with burn pattern interpretation happens when there is a strong factor that tips the fire dynamics physics in a different direction that might “naturally” occur.  An open door at the end of the hall can affect the ventilation of the fire, possibly pulling it away from the true area of origin to more heavily damage the area near the ventilation source.  Once ignited by radiant heat or flame impingement, an unusually heavy fuel load in one part of the room can cause greater damage than less loaded areas.  The good news is that these conditions can be observed at the scene and their effect included in the fire flow analysis.  But, the investigator must look for them and actively analyze their potential effects, not blindly go by the adage of “least to most, lowest part, there’s your area of origin.”
And then, there’s the postflashover scene.  When a fire proceeds through flashover and into the full room involvement phase, the chaotic air flow and “firestorm”-like conditions can alter, obscure, or obliterate the original fire patterns, as well as cause unusual physical damage.  The full room involvement stage typically produces heat flux readings at floor level of 170 kW/m2, which is sufficient to ignite most floor coverings and construction materials, creating extensive areas of low burning that may or may not be proximate to the area of origin.  Full room involvement can burn exposed wood on floors, window sills, and baseboards, even taking advantage of small gaps in wall construction to draw in air that causes ventilation effects.
Some of these potential postflashover effects mimic effects that can be caused by ignitable liquids, such as curling of vinyl floor tile and spalling of concrete.  Anytime a room reaches flashover, concrete will spall.  Unusual effects, like charring of the undersides of furniture, burning of floor coverings under furniture, burning under doors, and burning holes in floors have been observed with full room involvement fires.  The myth that effects like burning under furniture can only be caused when an accelerant is poured under the furniture does not hold true when everything in the room is on fire.  In a postflashover fire, the turbulent mixing between combustion gases and fresh air being drawn into the room causes high and variable heat fluxes that can cause irregular damage to floors and floor coverings.  They can also cause more intense burning around ventilation openings and melt synthetic fabrics and carpets.  In fact, in a post-flashover fire, the fire becomes ventilation-controlled and the most intense fire, and therefore the most intense thermal damage, may be near the air supply, such as open windows or doors.  Ventilation-controlled fires can, near ventilation sources, produce the characteristic V-pattern that is typically seen as an indication of fire origin.  In a ventilation-controlled fire, if a V-pattern is found near a door, for example, the investigator must consider whether this might have been an effect of the postflashover burning, rather than an area of origin. As these effects show, flashover makes the determination of the first material ignited much more difficult, as heavy burning may now occur in many places.
In summary, The key in tracing fire flow and finding the area of origin is, in reality, far more complex than the myth of most damage and lowest burning.  The investigator must observe and take into account all the physical properties of the compartment, including ventilation, fuel load, configuration, the stage of the fire (and whether or not flashover was achieved)—and the interaction between all of these factors plus the unique characteristics of that environment.

Today, fire scientists and investigators should have a better understanding of the nuances of low burn and deep burn patterns, as well as the various factors that create the appearance of separate multiple points of origin.  Continuous, targeted education regarding these indicators will ensure that investigators understand and effectively analyze the extent to which patterns are attributable to accelerant and/or other factors.
4.    Spalling
A Fire Marshal report includes an assessment of spalling evidence as follows:

The examination of the porch concrete floor disclosed an area of brown discoloration at the base of the north wall and in front of the door to the central hallway. This discoloration, or brown condition, is also an indication that a liquid accelerant burned on the concrete.

Spalling (i.e., brown discoloration or chipping or pitting of concrete or masonry surfaces) occurs when concrete, masonry or brick is exposed to a high rate of heating by flame or high levels of radiation from fuel.  Spalling is characterized by the loss of surface material resulting in cracking, breaking, and chipping or in the formation of craters on concrete, masonry, rock, or brick.  Fire-related spalling is the breakdown in surface tensile strength of material caused by changes in temperature, resulting in additional mechanical forces within the material. 


                                Concrete spalling above a doorway caused by fire

A mechanism of spalling is the expansion or contraction of the surface while the rest of the mass expands or contracts at a different rate; one example is the rapid cooling of a heated material by water.  Spalled areas may appear lighter in color than adjacent areas.  This lightening can be caused by exposure of clean subsurface material. Adjacent areas may also tend to be darkened by smoke deposition.  Another factor in the spalling of concrete is the loading and stress in the material at the time of the fire. Because these high-stress or high-load areas may not be related to the fire location, spalling of concrete on the underside of ceilings or beams may not be directly over the origin of the fire.

Controlled laboratory experiments have shown that while spalling may be caused by burning accelerant, it is more often caused by sustained heat from other sources.  It is critical that today’s investigators understand how to properly analyze spalling evidence.  For example, investigators should identify appropriate samples of adjacent materials and send those materials for laboratory testing to determine whether accelerant is present.

The presence of spalling at a fire scene cannot be taken as a definitive indicator that an accelerant was used in the fire.  Rather, the presence of the spalling should be explained, if possible, and then treated as one of many factors that enter into assessing the totality of the circumstances at the scene and their relationship to determining the heat source and first material ignited.


5.    Fire and Burn Intensity



                             Pulled bulb, showing that the heat was from the right
 


A Fire Marshal Vasquez testified as follows regarding his interpretation of burn intensity:

And aluminum melts at 1200 degrees normal. Wood fire does not exceed 800 degrees. So to me, when aluminum melts, it shows me that it has had a lot of intense heat. It reacts to it. That means its temperature is hot. The temperature cannot react. Therefore, the only thing that can cause that to react is an accelerant. You know, it makes the fire hotter. It’s not normal fire.
So when I found that the floor is hotter than the ceiling, that’s backwards, upside down. It shouldn’t be like that. The only reason that the floor is hotter is because there was an accelerant. That’s the difference. Man made it hotter or woman or whatever. Human being made it hotter.
The fire, itself, tells me that it’s a very aggressive fire; and, therefore, the fire was not a planned fire. It was a spur-of-the-moment fire.

Wood and gasoline burn at essentially the same flame temperature.  In the early 1990’s, the “widely held belief” among fire investigators was that the flames of a wood-fueled fire are cooler than those fueled by petroleum products.  Thus, investigators would often conclude that a “hot fire” must have had an accelerant ignition.  Scientists now know that flame temperatures for normal fuels against liquid fuels are similar, and compartment temperatures alone cannot be used to distinguish whether ordinary or liquid fuels were involved.  It is critical that today’s fire investigators understand the significance of flame temperature and heat release rates, and how these factors should be viewed within the context of other indicators.
If the investigator knows the approximate temperature required to produce an effect, such as melting, color change, or deformation a material, an estimate can be made of the temperature to which the material was raised.  This knowledge may assist in evaluating the intensity and duration of the heating, the extent of heat flow, or the relative rates of heat release from fuels.  When using materials such as glass, plastics, and white pot metals for estimating temperature, the investigator is cautioned that there is a wide variety of material properties for these generic materials.  The best method for utilizing such materials as temperature indicators is to take a sample of the material and have its properties ascertained by a competent laboratory, materials scientist, or metallurgist.
In addition to the wood and gasoline burning at essentially the same flame temperature, the turbulent diffusion flame temperatures of all hydrocarbon fuels (plastics and ignitable liquids) and cellulosic fuels are approximately the same, although the fuels release heat at different rates. Burning metals and highly exothermic chemical reactions can produce temperatures significantly higher than those created by hydrocarbon- or cellulosic-fueled fires.
In summary, fire patterns are generated by one of two mechanisms: the spread of the fire or the intensity of burning.  As discussed above, fuel composition, rate of heat release, location, and ventilation differences may lead to differences in the intensity patterns that do not necessarily point to the area where the first fuel was ignited.  Patterns that arise from the growth and movement (spread) of the fire are invariably better indicators of the area of origin.  It may be difficult, however, to distinguish movement patterns from intensity patterns.  Further, some patterns display a combination of intensity and movement (spread)
indicators.

•          Holes in the floor may be caused by glowing combustion, radiation or an ignitable liquid.
•          There is no justification that the appearance of large, curved blisters is an exclusive indicator of an accelerated fire.
•          The presence or absence of spalling should not, in and of itself, be construed as an indicator of the presence or absence of a liquid fuel accelerant.
•          Inverted cone patterns have been interpreted as proof of flammable liquid fires, but any fuel source that produced flame zones that do not become vertically restricted can produce inverted cone patterns.


6.    Crazed Glass





                         Crazing of glass in a fire where no accelerants were used

Crazing is a term used in the fire investigation community to describe a complicated pattern of short cracks in glass.  A Fire Marshal made the following statement regarding crazed glass in his report in an arson case:

The pieces of broken window glass on the ledge of the north windows to the northeast bedroom disclosed a crazed ‘spider webbing’ condition. This condition is an indication that the fire burned fast and hot.

Crazing is the result of the rapid cooling of glass in a hot environment by the application of water spray.  Fire scientists and investigators have concluded that it no longer has any value as an indicator.  Today’s investigators should not mention the presence of crazed glass in a fire scene report.  If crazed glass were mentioned, corrective action would be taken immediately.
Incendiary indicators, including but not limited to those discussed above, are subject to numerous variables that require continuous study and evaluation.  Scientific understanding of the indicators has continued to advance as additional experiments are conducted. Training must ensure that fire investigators clearly understand all incendiary indicators and their limitations, including the possible effects of phenomena such as flashover and associated radiation, ventilation, smoldering debris and drop-down effects.  Whatever training is provided must include an environment in which investigators and scientists are free to exchange information and engage in honest and open dialogue regarding fire behavior and incendiary indicators.

Confirmation of Accelerant Through Laboratory Testing
In one arson case, ten samples were sent for testing. None of the samples tested positive for accelerant.   In another case, an unspecified number of samples were sent for testing, and one (under the aluminum threshold of the front door) tested positive for accelerant.
At the time these cases occurred, positive laboratory results were accepted if they were available, but they were not considered necessary to reach the conclusion that the fire involved intentional use of an accelerant.
As technology advanced, fire scientists and investigators developed a better understanding of the importance of confirmatory testing. Experts have also noted that technology used in gas chromatography/mass spectrometry and other laboratory testing is more sensitive today than it was in the early 1990’s. As a result, laboratory tests are better able to detect evidence of accelerant than they were two decades ago. Due to the passage of time, re-testing of samples taken in the Willis and Willingham cases is not an option.


Laboratory testing is relied upon more heavily today due to improvements in technology and enhanced expectations of lawyers and judges. Fire investigators should have a thorough understanding of the importance of laboratory testing as a tool for confirming the theory of a case, especially where arson is suspected.

The Five Most Common Arson Myths
1.  The lowest and deepest charring indicates the point of origin in a fully involved room.
2.  In a fully involved room, an experienced investigator can identify patterns produced by ignitable liquids on the basis of visual observation alone.
When a fire breaks out, a phenomenon called flashover can occur. Flashover is a transition point at which heat causes almost everything in a room to catch fire. When it happens, the natural patterns of the fire can be obscured or destroyed. V-shaped burn patterns, which often occur after a flashover, can be misinterpreted to indicate arson.
3.  Flammable liquids burn at a higher temperature than ordinary combustibles.
It's a common misconception that gasoline burns at a higher temperature than wood.  It's actually the amount of ventilation that determines the temperature of the fire, not the nature of the fuel.
4.  Spalling or flaking of concrete, especially in a "puddle" shape, is an indicator of the presence of burning ignitable liquids.
Fire tests have shown that "puddle" shapes can occur after a flashover.
5.  Heat rises and fire always burns upward. Floor level burning is therefore an indication of an incendiary fire.
The idea that a fire will not burn downward unless it has "help" is a simplistic explanation of fire behavior that doesn't take into account the flashover phenomenon. It was widely believed that burning on the floor, particularly under furniture, indicated an origin on the floor, and pointed toward arson.

Additional Myths Still in Favor in Some Quarters Today
6.  Multiple low burns, or multiple V-shaped burn patterns, even if they are burned together, indicate multiple origins.
7.  Using models, it is possible to calculate fire behavior precisely.
8.  A narrow V-pattern indicates a rapidly burning fire, whereas a wide V-pattern indicates a "normal" fire.
9.  Although flashover and full room involvement can generate ambiguous patterns, flashover is rare. (Flashover is a transition point at which you go from having a fire in a room to a room on fire).
10.         A melted aluminum threshold is unusual in a "normal" fire, and tends to indicate the presence of ignitable liquids.

Myths That Have Been Largely Discredited, And Are Only Used By Those Profoundly Unaware Of The Science
1.  "Crazed" glass, broken throughout, indicates that the glass was rapidly heated. Further, the size of the crazing can provide information about the origin.
2.  The size and appearance of char blisters can provide information about what was burning, and how rapidly it was burning.
3.  An unconfirmed canine alert constitutes valid evidence of an accelerant.
4.  The temperature of a fire follows a "standard time-temperature curve."
5.  The heat release rate of a fire can be predicted by knowing the weight of combustible fuels in a room.

Metropolitan Engineering, Consulting & Forensics (MECF)
Providing Competent, Expert and Objective Investigative Engineering and Consulting Services
P.O. Box 520
Tenafly, NJ 07670-0520
Tel.: (973) 897-8162
Fax: (973) 810-0440

http://metroforensics.blogspot.com/

We are happy to announce the launch of our twitter account.  Please make sure to follow us at @MetropForensics or @metroforensics1

Metropolitan appreciates your business.
Feel free to recommend our services to your friends and colleagues.


[1] J. Lentini. Scientific Fire Analysis, LLC. Presentation to the committee. April 23, 2007. Available at www7.nationalacademies.org/stl/April%20Forensic%20Lentini.pdf.
[2] NFPA 921 Guide for Explosion and Fire Investigations, 2008 Edition. Quincy, MA: National Fire Protection Association.

CAUSE AND CONTRIBUTING FACTORS OF FAILURE OF GEARED WIND TURBINES, Part 1


CAUSE AND CONTRIBUTING FACTORS OF FAILURE OF GEARED WIND TURBINES, Part 1
Wind turbine on fire

The geared wind turbines continue to be plagued by numerous gearbox (more accurately the bearings within the gearbox), blade, mechanical, weather-related (e.g. lightning), design and maintenance issues. 

Just yesterday Siemens announced that the wind projects are not viable without heavy government subsidies. The failure of the bearings located within the gearbox is the most significant problem associated with the turbines This year, Siemens, a main manufacturer of wind turbines, reported a charge of 48 million Euros for inspecting and replacing defective main bearings in some onshore wind turbines. Structural and mechanical failures (which can result in a tower collapse) are primarily due to control system errors and lack of effective maintenance. 

If it was not for the government subsidizing of these systems, they would have never been built that way. This blog addresses the major causes of failure of wind turbines.

Wind turbines generate electricity through the wind-induced rotation of two to three aerodynamic blades located around a rotor. The rotor is connected to the main shaft that is connected to a generator that in turn spins to create electricity. We have seen wind turbines smaller than 100 kW and as large as 6,000 kW. The wind turbines can generate electricity to run a single piece of equipment (e.g. a water irrigation pump) at a particular facility or can produce electricity for sale to a power grid. 

The annual wind turbine capacity of the United States continues to grow exponentially. This growth is fueled by investment tax credits, federal goals of mandatory generation of electricity from renewable sources, rising energy demand, and other factors.

The biggest wind turbine manufacturers include General Electric, Vestas, Siemens, Clipper, Mitsubishi, Suzlon, Alstom, and Gamesa.

Crews lift a blade assembly onto the nacelle of Gamesa's G9X-2.0-megawatt turbine at the NWTC. 

The main components of a wind turbine system are:

· Tower, made from tubular steel, concrete, or steel lattice;
· Foundation for the turbine’s tower, nacelle and rotor blades;
· Nacelle; it houses the mechanical, electrical, electronic and other components of the turbine;
· Rotor Blades that rotate and cause the rotor to spin;
· Transformer;
· Generator that produces AC electricity from mechanical (rotational) energy; usually an induction generator;
· Rotor; it is formed by the blades and the hub;
· Brake that stops the rotor;
· Tail, but not all turbine types have tails;
· Gearbox that changes between the low and high gear shaft to increase the rotational speed to 1,000-1,800 rpm;
· Electronic control panel ;
· Shafts (low and high speed) connecting the rotor to the generator
· Blade power control system (controls the blade pitch and the yaw);
· Anemometer (wind speed control) and wind vane (wind direction control)

Anatomy of a wind turbine


A commercial, utility-scale wind energy generation facility typically consists of tens to hundreds of wind turbines capable of generating hundreds of megawatts of renewable energy. In addition to the wind turbines, other facilities associated with a wind farm project include access roads, temporary crane paths, underground power collection lines, aboveground generation tie lines (gen-tie), collector substations, interconnection switch yard, several permanent and temporary meteorological towers, and operations and maintenance building.

A 6,000-kW offshore wind turbine


The useful life of these wind turbines is supposed to be 20 years. However, the turbines have been plagued by numerous problems and this 20-year life is rather a utopia than anything else. Gearboxes and bearings in wind turbines, more than those in any other application, tend to fail prematurely. In fact, at some wind projects, up to half of all bearings inside the gearboxes fail within a few years. 

There are several reasons for this, including the poor understanding of gear functioning during storms and gusty winds, relative immaturity of the technology and industry, the rapid evolution of turbines to extra-large sizes, poor understanding of turbine loads, and an emerging (and largely unexplained) failure mode in turbine bearings called axial cracking.

Axial cracking in the gearbox of the wind turbine


The fact that the manufacturers of the turbines provide only a two-year warranty, is pretty good evidence of the reliability of this technology at this time. For example, the catastrophic gear box failures appear to be caused primarily by induced mechanical voltage straying through the gearbox, pitting the bearings. This has happened, in some cases, within 18 months after the turbine was placed into service.


Insurance for Wind Farms and Turbines

Like any piece of complex machinery operating under stress, turbines can fail. They break. They develop faults. They are improperly constructed. They are improperly maintained, and so on. And without the right care and protection policy in place, the resultant claim can quickly spiral out of control. For the owner and investor, this can lead to lost revenue and operational downtime; at worse, it means absorbing an increasingly daunting repair bill. We outline the top causes for turbine failure and explain what to do when things go wrong.


Wind farm insurance packages can include: construction insurance, physical damage, and third-party liability insurance coverage for delays in building of a wind farm, loss of earnings, and business interruption once the operation is running. Specifically, wind turbine coverage can compensate the policyholder for production losses if the wind farm’s annual wind levels fall below forecast.
Based on our investigations, we list below the most commonly encountered causes of wind turbine failures:

· Bearings and Gearbox issues – this is the Achilles Heel of the Gear-Driven Turbine
· Lightning strikes
· Blade design, manufacturing and installation issues
· Mechanical Breakdown (generators and transformers, burning the windings due to overspeed, etc.)
· Hydraulic failures
· Wind turbine and wind farm electric systems
· Grid failures
· Nacelle fire
· Improper handling during transportation, construction and improper assembly
· Human error(s) in O&M, construction and design
· Turbine collapse
· Natural Catastrophic events
· Yaw motor events
· Poor O&M arrangements
· Axial Stress
· Foundation damage
· Icing
· Accumulation of bugs, dirt and other debris
· For offshore turbines, the power converter suffers from high failure rates

We will address these failure modes below. 

Fires

In a typical year we expect to see total losses – typically caused by a fire – whereby the unit can no longer be repaired and is declared a total loss. In these instances, the most common causes are internal component failure or a buildup of material in lubricants. This can start an escalating spiral of sequential events and a rather spectacular – if not expensive – mechanical fire.

Fires are the second highest cause of catastrophic turbine failure

Extreme Weather

In occasional circumstances, extreme weather is also responsible for failure – whereby the wind speed and the elements simply become too much for the engineering dynamics of the machine. Brakes fail, blades seize up and the chain of events continues to make things worse.

Root Causes of Generator Failure

The main root causes of failure of generators at wind turbine sites include but are not limited to:

· Failure to follow recommend maintenance practices regarding the lubrication procedures, collector systems, etc.; mechanical or electrical failure of bearing, rotor lead failures, cooling system failures leading to excessive heat and fire.
· Lightning strikes, wind loading, weather extremes, lubricant contamination, thermal cycling, etc.
· Misalignment and other improper installation, excessive vibration, voltage irregularities, convertor failure, improper grounding, overspeed that results in burning of the windings, etc.
· Manufacturing and/or design failures, such as, loose components (wedges, banding), inadequate electrical insulation, transient shaft voltages, poorly designed/crimped lead connectors, rotor lead failures, the presence of other components inside the nacelle that complicate service, etc.
· For generators that are less than 1,000-kW, the most common failure mode is damage to rotor, following by stator, bearings, collector rings and miscellaneous generator failures. For generators that are between 1,000- and 2,000-kW, the most common failure mode was associated with the bearings, followed by collector rings, rotor, stator, cooling system, rotor leads and miscellaneous failure modes. For generators that were greater than 2,000-KW, the most common failure mode was associated with bearings, followed by stator, stator wedge, rotor, rotor leads, collector rings and miscellaneous failures. 

Maintenance is the critical factor affecting machinery life. Proper repairs are also critical to the reliability and longevity of the turbine generator.

Damage to the generator windings due to over-speed and subsequent overheating of the windings

Then there are the gearbox and blade lightning strikes.
Again, these create a spectacular display but also a spectacularly large loss – with the resultant damage often requiring either extensive turbine down time and a complex replacement or repair.

Blade Failure Modes

The main causes of failure of turbine blades include: lightning strikes, foreign object damage, poor design, material failure, power regulator failure. A combined thermal and stress analysis of a lightning strike model of typical wind turbine blade material (including E-glass composite layups) shows that the fiberglass material immediately surrounding the lightning attachment location becomes damaged due to plastic deformation. Depending on the magnitude and number of lightning strikes, the blade has the potential to fail under an extreme static gust load, under fatigue, or a combination of the two.

Turbine blade damaged by lightning strike.


Accumulations of bugs, oil, and ice on the blades will also reduce power as much as 40%. Regular cleaning of the blades has become a maintenance requirement. Included in the hours of down time for cleaning the blades is ice built-up when the ice causes the airfoil shape to be changed and the turbine cannot produce power.

Broken wind blade


Bearing Failures - The Achilles Heel of Geared Wind Turbines

No matter what type of turbine model, mainshaft bearings are common failure points. The main reason: spherical roller bearings are not the optimal bearing configuration. Large amount of radial internal clearance (RIC) are needed to facilitate original bearing assembly at the manufacturer. Although this simplifies the assembly at the turbine OEM, this clearance is not well suited for handling axial loads. The proper bearing configuration would be a pre-loaded tapered roller bearing, but this would have increased both turbine assembly time, as well as purchased cost. 

As a result of this configuration, the thrust from the wind causes the mainshaft to move axially towards the gearbox until the clearance has been absorbed, hence unseating the upwind row while the downwind row now sees the majority of the load.

The primary failure mode of the mainshaft bearing is macropitting (spalling) of the downwind race. The unloaded upwind row will then skid and skew as result of having no roller tractions, creating a second failure mode of micropitting. The micropitting is also called ‘grey staining’ or ‘frosting’. 

This consists of microscopic cracks only a few microns deep (about .0001 inches). Individually these cracks are too small to be visible. As they accumulate they appear as grey stains on the roller surface. Eventually the bearing roller starts to shed its cracked and weakened surface losing a small bit of its precision tolerance. Furthermore, this contaminates the oil with microscopic super hard steel particles most of which are too small to be filtered out. Why does grey staining begin? Typically it is a breakdown of the oil film that separates the rollers from the races.


There are many opinions in the public domain summarizing common indications of specific operating conditions in conjunction with premature failures in wind turbine applications: 

· periods of heavy and dynamic loads/torques – leading to vibrations and rapid load changes (e.g. transient raceway stress exceeding 3.1 GPa, heavy loads of 15,000 per year, impact loads). Such transient events can include: grid loss, high wind shutdowns, wind gusts, curtailments, control malfunctions, generator short circuits, resonant vibration, misc emergency stops. Although these reversals are infrequent, they can be severe.
· depending on turbine type, additional radial and axial forces by the rotor, axial motion of the main shaft – leading to dynamical loading, higher stresses of gearbox components especially in the first stage
· occasional connecting and disconnecting of the generator to/from the power grid – leading to torque reversals and bouncing effects (which e.g. can lead up to 2.5-4 times higher nominal torque and impact loads)
· rapid accelerations/decelerations and motions of the gearbox shafts
· misalignment, structural deformations (nacelle hub, housings)
· lubricant compromise between needs of gears and bearings as well as between low and high speed stages, insufficient oil drains and refill intervals
· harsh environmental conditions – possible large temperature changes and consequently larger temperature differences between the bearing inner ring and housing than expected when starting up, dust, cold climate, moisture and salt water (especially for off-and near-shore turbines)
· idling conditions – leading to low load conditions and risk of skidding damage (adhesive wear) and wear in the low running stage
· conflicting design needs, e.g. increasing rolling element size will increase the load capacity but simultaneously increase the risk for cage-and roller slip and sliding damage

As stated above, bearings may fail due to other reasons not covered by best practice standards and from other industrial experiences. 

Statistical evaluations of onshore and offshore wind turbines indicate clearly a correlation between failure rate, wind speed and heavy and fluctuating loads.

Metropolitan Engineering, Consulting & Forensics (MECF)
Providing Competent, Expert and Objective Investigative Engineering and Consulting Services
P.O. Box 520
Tenafly, NJ 07670-0520
Tel.: (973) 897-8162
Fax: (973) 810-0440
E-mail: metroforensics@gmail.com
We are happy to announce the launch of our twitter account. Please make sure to follow us at @MetropForensics or @metroforensics1
Metropolitan appreciates your business.
Feel free to recommend our services to your friends and colleagues.